1 LED fl ashes:
The battery is empty, recharge the battery.
All LEDs blink:
The battery temperature is too low. Remove the
battery from the equipment, keep it at room tem-
perature for one day. If the fault reoccurs, this me-
ans that the rechargeable battery has undergone
exhaustive discharge and is defective. Remove
the battery from the equipment. Never use or
charge a defective battery.
6. Operation
You can put the equipment into operation after
you have thoroughly read the installation and ope-
rating instructions. Pay attention to the following
points:
Make sure that the equipment is set up se-
curely.
Check that the discharge line is fitted cor-
rectly.
Lower the pump into the well or shaft using a
securing cable or hang it inside the rainwater
barrel.
The device starts automatically after you have
pressed the On/Off switch (7).
Make sure that the equipment does not run
dry.
To switch off the device, please press the ON/
Off switch (7) again.
Dry-run safeguard:
The pump is equipped with a dry-run safeguard
and will switch off after approx. 20 seconds of no
medium being pumped. Switch off the pump with
the On/Off switch (7) or remove the battery in or-
der to reset the triggered dry-run safeguard. Then
the pump will be fully functional again. When you
start up the pump, check that the minimum level
of water is available.
7. Cleaning, maintenance and
ordering of spare parts
Danger!
Always pull out the battery pack before star-
ting any cleaning work.
For mobile applications, the equipment
should be cleaned with clear water after every
usage.
Use a water jet to remove any lint or fibrous
Anl_GE_SP_18_Li_SPK9.indb 19
Anl_GE_SP_18_Li_SPK9.indb 19
GB
particles that may have become trapped in
the housing.
Remove sludge from the shaft bottom and
clean the shaft walls every 3 months.
7.1 Cleaning the paddle wheel
If a lot of deposits collect in the housing, the bot-
tom part of the equipment must be dismantled as
follows:
1. Disconnect the intake cage from the housing.
2. Clean the paddle wheel with clear water. Im-
portant! Do not put down or rest the equip-
ment on the paddle wheel!
3. Assemble in reverse order.
7.2 Maintenance
There are no parts inside the equipment which
require additional maintenance.
7.3 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.Einhell-Service.com
8. Disposal and recycling
The equipment is supplied in packaging to pre-
vent it from being damaged in transit. The raw
materials in this packaging can be reused or
recycled. The equipment and its accessories are
made of various types of material, such as metal
and plastic. Never place defective equipment in
your household refuse. The equipment should
be taken to a suitable collection center for proper
disposal. If you do not know the whereabouts of
such a collection point, you should ask in your
local council offi ces.
9. Storage
Store the equipment and accessories in a dark
and dry place at above freezing temperature.
The ideal storage temperature is between 5 and
30 °C. Store the electric tool in its original pa-
ckaging.