11. Troubleshooting guide
Faults
The equipment
does not start
The equipment
does not pump
Insuffi cient pumping
rate
The equipment swit-
ches off after briefl y
running
Anl_GE_SP_18_Li_SPK9.indb 21
Anl_GE_SP_18_Li_SPK9.indb 21
GB
Cause
Battery is not correctly inserted
- Intake sieve clogged
- Discharge hose kinked
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Battery performance decreasing
- Motor circuit-breaker switches the
equipment off due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment off
- 21 -
Remedy
Remove battery and insert again
- Clean intake sieve with water jet
- Unkink the hose
- Clean intake sieve
- Clean equipment and replace wear
parts
- Check the battery performance and
charge the battery if necessary
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
13.12.2021 10:51:58
13.12.2021 10:51:58

Publicidad

loading

Este manual también es adecuado para:

Ge-sp 18 li