Minimum superheat alarm. The value set in A20 has been reached. Activates the alarm
relay and the audible alarm.
Minimum superheat alert. The value defined in A23 has been
screen.
Maximum evaporating pressure alarm. The value defined in A26 has been reached. Acti-
vates the alarm relay and the audible alarm.
Minimum evaporating pressure alarm. The value defined in A29 has been reached. Acti-
vates the alarm relay and the audible alarm.
Indicates that a defrost is being performed. Only displayed on screen.
Password request. See parameters b10 and PAS (See page 28). Only displayed on screen.
Shown sequentially with the temperature: The controller is in demo mode,
the configuration has not been made.
Calibration ongoing, therefore, avoid, as far as possible, opening the cold room during
the process.
Flashing light with temperature: Configuration has been changed from 1 to 2 evaporators
or vice versa.