NOTE
Auto Changeover
• When in Auto Mode, the unit selects the operating mode (cooling, heating or fan only) based on the user set point
temperature.
• If the Auto mode is uncomfortable, you can select the desired conditions manually.
Cooling
• If there is a demand for cooling, unit will start approximately 1 minute after mode is selected.
• When the room temperature reaches the set temperature, the outdoor unit stops and the indoor unit fan runs at extremely
low speed.
Heating
• If there is a demand for heating, unit will start approximately 3 to 5 minutes after the mode is selected.
• After the heating operation has stopped, fan may continue to run for approx. 30 seconds.
• When the room temperature reaches the set temperature, the outdoor unit stops and the indoor unit fan runs at extremely
low speed.
• During defrost operation, the fan stops so that cool air is not discharged. ("
When restarting the operation after stop
When the unit is attempted to restart immediately after it was stopped, the unit can not start for approx. 3 minutes this is to
protect the compressor.
8°C Operation (For object pre-heating)
The air conditioner can control the heating temperature to about 8°C in the heating mode.
The 8°C heating operation requires settings with the wired remote controller. Ask the installer or dealer for the settings
according to the installation manual of the indoor unit.
Start
1
Set the displayed temperature to 18°C in the heating mode by pushing [
2
Set the displayed temperature to 8°C by pushing [
Stop
1
Set the displayed temperature to 18°C by pushing [
• The air conditioner returns to the normal Heat mode. Select a desired temperature and operation mode.
NOTE
• The discharged air temperature is lower than that in the normal heating operation.
• The room temperature may not be heated evenly depending on the remote controller installation location.
• The room temperature may not reach 8°C depending on the room size or the installation conditions.
• Setting for fan speed is available during the 8°C heating operation.
The 8°C heating operation is cancelled in the following cases.
•When operation is stopped with ON/OFF button.
•When another operation mode is selected.
•When temperature setting or operation mode is changed or operation is started / stopped by the wireless remote controller
or the central control remote controller.
• When this operation mode is used, observe proper operating hours and periodic maintenance by service staff is
recommended.
97-EN
" Pre-heat is displayed.)
] setting button.
] setting button for at least four seconds.
] setting button.
– 49 –
5
OFF timer operation
OFF timer: The indoor unit stops when the set time is reached.
1
OFF timer button
Push the OFF timer button during air conditioning operation.
• "
" and "OFF" light and "SETTING" and timer indicator flash.
2
Select the OFF timer time
Push the setting button to set the time.
• The OFF timer time can be set to 0.5 h (30 min), 1 h, 2 h, ∙ ∙ ∙ up to 24 h.
• If you do not push any button for 30s, the OFF timer setting will be cancelled.
3
Push the OFF timer button
"SETTING" disappears, the timer indicator changes from flashing to lighting, and the OFF timer starts.
• The timer indicator on the OFF timer operation is displayed with countdown.
Cancelling the timer
1
Push the OFF timer button
The timer indicator disappears.
NOTE
Even if air conditioning is turned on or off with the ON/OFF button during OFF timer operation, the OFF timer operation
continues.
1,3
2
98-EN