Connecting the Light Bar
All Color Changing Colorfalls and wiring components are connected via quick-connect plug.
Color Changing Colorfalls will not operate if plugs are aligned incorrectly. The connectors are
keyed to ensure the connections line up properly. Color Changing quick-connect plugs carry
both AC and DC current to the in-line driver. Moisture entering the connections will allow the
AC and DC current to cross which can damage the lighting system.
Quick-connect plugs are gasketed for outdoor use and must be fully tightened to
prevent water infiltration. Quick-connect plugs are not waterproof and should not be
submersed. Dielectric grease is included and should be used in all connections to eliminate
water infiltration.
The transformer must be plugged into a properly grounded GFCI outlet. Please follow the
connection diagram below for proper installation.
Transformer
Multiple Colorfalls can be connected by using Atlantic Color Changing Lighting
components. For installations up to 30 watts, purchase additional Splitters (CCBSX4) and a
larger Transformer (TRANS60).
To connect multiple Colorfalls over 30 watts, purchase an InfiColor 3 Light Wiring Kit
(CCSM30X3), Splitters (CCBSX4) and 150 Watt Transformer (TRANS150).
INFICOLOR SMART MODULE
Installation
The InfiColor Smart Module is weatherproof, but must be mounted above the ground on a
wall or post within reach of a properly grounded GFCI outlet. Do not submerse the Control
Module or expose it to heavy rainfall.
• Install the Module in a well-ventilated area to ensure that the module operates within its
specified working temperature.
• Verify that the Smart Module input voltage is 12 volt AC, class 2 circuit. We recommend that
you use the transformer provided with this unit.
• Use dielectric grease on all connections and ensure that all cable connections are secure.
• Do not connect the power before the cord connections are finished.
• Do not cut or alter any round cords. Cutting or damaging any round cord will void the warranty.
CONNECTING LIGHTING TO MODULES
For all connections, apply included dielectric grease to the pins of the plugs. Line up the keys of
the plugs using the arrows as a guide. Tighten the threaded ring, then wiggle the connection
and retighten the threaded ring 2-3 times until firmly seated.
NOTE: Failure to properly align plugs will result in damage to components.
INFICOLOR MOBILE APP
To connect your mobile device to the Smart Module, be sure the Module is plugged in and
open the InfiColor App. The app should populate your Smart Module on the opening screen.
Simply select the Module name. Please note the Module can be connected to one mobile
device at a time. The Single Zone Module will only modify the settings of Zone 1 on the app.
4
Smart Module
LED Light Strip