Descargar Imprimir esta página

Siemens 7ME3601-4 Guía Rápida página 39

Publicidad

Idiomas disponibles

Idiomas disponibles

4.2
Alarm Letter Codes and Descriptions
Letter Code
S
Spacing
0
ZeroMatic
E
Empty
R
F
A
Aeration
M
Memory
K
Makeup
I
Interface
P
The display shown below indicates where the Alarm Codes appear on the LCD display
screen.
SITRANS FUH1010 Quick Start
Operating Instructions (Compact), 12/2008, CQO:QSG010 Revision A
All manuals and user guides at all-guides.com
Alarm
Transducer spacing may need readjustment.
ZeroMatic signal fault.
Pipe is empty.
Rate
Flow above High setting or below Low setting.
Fault
Three continuous seconds without new data update.
Current aeration percentage exceeds the alarm set point.
Last valid reading for a selected interval during Fault condition.
In-Process Makeup occurred.
Liquid Vs exceeds interface alarm set point.
Pig
Pig passage detected (optional).
Alarm Codes
Troubleshooting/FAQs
4.2 Alarm Letter Codes and Descriptions
Description
37

Publicidad

loading

Este manual también es adecuado para:

Sitrans fuh1010