1.5
Intended uses
These specific vacuum cleaner models have been designed, built and protected for vacuuming dusts and
solid materials only, using special filters.
Warning!
Always use specific filters for the type of dust or materials to be vacuumed.
Any other use is considered IMPROPER.
The vacuum cleaner is in any case intended for professional industrial use.
1.6
Allowed environmental conditions
To ensure the correct operation of the vacuum cleaner, this must be positioned protected against
atmospheric agents (rain, hail, snow, fog, dusts in suspension, etc.) with an environmental running
temperature between 5°C and 45°C and relative humidity not above 70%.
The work environment must be clean, well-enough lit and devoid of explosive atmosphere.
1.7
Noise level
Noise level readings were taken in accordance with the provisions of Machine Directive 2006/42/CE
standards.
Sound tests performed on this specific vacuum cleaner model have been taken from a distance of 1 meter
and from a height of 1,60 meters, showing an acoustic pressure no higher than:
The vibrations transmitted by the machine are lower than 2,5 m
Attention!
Pursuant to articles L.D. 81/08, workers exposed to sound pressure levels above 85 dB(A) must be
protected by special individual protection devices.
It is therefore necessary, if such working conditions exist, to provide workers with such approved
individual protection devices and to inform them of the risks relating to noise exposure.
1.8
Storage
Remove the filter and clean it, empty the container and store the vacuum cleaner in a place protected
against atmospheric agents with a temperature between 0°C and 40°C. Cover with a nylon sheet to prevent
accumulation of dust.
1.9
Scrapping
In case of scrapping, all the component parts of the vacuum cleaner will have to be disposed of through
adequate disposal channels in accordance with applicable legislation.
Before scrapping, all plastic and rubber parts will have to be separated from the electrical material. Parts
made of plastic, aluminium and steel only may be recycled if collected by special centres.
75 dB (A)
2
/s.
ENGLISH- 4 -
Information Section