Configuration Of Connection Pipe - HTW IX80 Manual De Usario E Instalación

Aire acondicionado splot
Ocultar thumbs Ver también para IX80:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Configuration of connection pipe

1. Standard length of connection pipe
● 5m, 7.5m, 8m.
2.Min. length of connection pipe is 3m.
3.Max. length of connection pipe and max. high difference.
Max length
Cooling
of connec-
capacity
tion pipe
5000Btu/h
(1465W)
7000Btu/h
(2051W)
9000Btu/h
(2637W)
12000Btu/h
(3516W)
18000Btu/h
(5274W)
4. The additional refrigerant oil and refrigerant charging required after prolonging
connection pipe
● After the length of connection pipe is prolonged for 10m at the basis of
standard length, you should add 5ml of refrigerant oil for each additional 5m
of connection pipe.
● The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):
Additional refrigerant charging amount = prolonged length of liquid pipe ×
additional refrigerant charging amount per meter
● Basing on the length of standard pipe, add refrigerant according to the
requirement as shown in the table. The additional refrigerant charging amount
per meter is different according to the diameter of liquid pipe. See the
following sheet.
Max height
difference
15
5
15
5
15
5
20
10
25
10
Cooling
capacity
24000Btu/h
(7032W)
28000Btu/h
(8204W)
36000Btu/h
(10548W)
42000Btu/h
(12306W)
48000Btu/h
(14064W)
32
Max length
Max height
of connec-
difference
tion pipe
25
30
30
30
30
10
10
20
20
20

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido