MODELS
DIMENSIONS cm
POWER SUPPLY
MAXIMUM ABSORPTION A
MAXIMUM POWER kW
POWER SUPPLY CABLE
The data plate is on the front (see diagram in electric connection item) and has all the data necessary for the connection.
When fitting, the appliance must be leveled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishes, etc., these should be in flameproof material; otherwise
it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that fire prevention standards are observed.
Always comply with the following points during installation:
-
Ensure that mains voltage complies with the voltage indicated on the specification table of the
appliance
-
All electrical installations must comply with local standards. All standards issued by national electrical authorities
must be complied with.
-
When circuit breakers are used, they must be suitable for a minimum of 30 mA.
-
Avoid obstruction of air intakes or outlets with objects (fabric, walls, etc).
-
Keep hot air off of the induction appliance (for example when several appliances are next to one another, or behind one
another, or when an appliance is separated by a separate air duct.
-
The induction appliance must not be placed near or on hot surfaces.
GB
GENERAL TECHNICAL DATA
Minimal pan diameter:
Relative humidity:
Operation Ambient temperature:
Voltage tolerance:
Supply frequency:
TECHNICAL DATA TABLE
PCI-74ET PCIT-74ET PCI-78ET PCIT-78ET PCIW-74ET
40x70x90h
40x70x29h
400V/3
400V/3
50/60Hz
50/60Hz
14,4 A
14,4 A
10 kW
10 kW
4x1,5 mm²
4x1,5 mm²
INSTRUCTIONS FOR INSTALLATION
INSTALLATION
IE
120 mm
10% to 90% non-condensing
0°C ÷ 40°C
-10% ÷ +6%
50 – 60 Hz
80x70x90
80x70x29h
400V/3
400V/3
50/60Hz
50/60Hz
29 A
29 A
20 kW
20 kW
4x4mm²
4x4mm²
41
PCIWT-74ET
40x70x90
40x70x29h
400V/3
400V/3
50/60Hz
50/60Hz
7,2 A
7,2 A
5 kW
5 kW
4x1,5 mm²
4x1,5 mm²