Descargar Imprimir esta página

Cameo CLZW600-D Manual De Usuario página 10

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 39
SYSTEM INFORMATION (System Info)
Press MODE to access the device settings selection menu (--- Menu ---). Using the arrow keys, select the menu item "System Info"
(observe arrow) and confirm with ENTER.
------------------- Menu -------------------
DMX Address
DMX Mode
Stand Alone
Slave
Settings
System Info
Use the UP and DOWN controls to select the desired sub-menu item, and press ENTER to display the corresponding information.
System Info
Firmware
=
Temperature
=
Operation Hours
=
MANUAL LOCKING FUNCTION
In addition to the ability to automatically protect the spotlight from accidental and unauthorised operation (see "Settings" - "Auto-lock"), the
controls can also be locked manually. Press and hold the UP and DOWN controls simultaneously for approximately 5 seconds. If an attempt
is made to change settings, "Locked!" will appear in the display, and changing the spotlight's settings via the controls is no longer possible.
After approx. 1 minute, the current operating mode is displayed again. To unlock, press and hold the UP and DOWN controls simultaneously
for approximately 5 seconds. The display will show the previously displayed information.
SET-UP AND INSTALLATION
Thanks to its integrated plastic feet, the spotlight can be positioned in a suitable location on a level surface. Mounting to a traverse is
possible using an Omega bracket which is attached at the centre of the device base (A) or else by means of two Omega bracket, which are
mounted at the outer attachment positions (B). Two Omega brackets are included,suitable traverse clamps are optionally available. Ensure
firm connections and secure the spotlight at the specified position (C) using a suitable safety cable.
Setting of the beam direction of the LED unit occurs independent of the device base, with the assistance of the wing nuts on the side.
Important: Overhead installation requires extensive experience, including the ability to calculate the threshold limits for load capacity, a
knowledge of the installation material to be used and the ability to carry out regular security checks on all installation materials and the
spotlight itself.
If you do not possess the appropriate qualifications, do not attempt to carry out the installation yourself: draw on the help of a professional company.
10
Displays device
Main CPU
firmware
Led driver
Displays temperature of
LED
LED unit
Unit
Displays operating time
xx:xx h
B
Vx.xx
Vx.xx
xx °C / xx °F
°C (= display in degrees Celsius)
°F (= display in degrees Fahrenheit)
Displays total operating time in hours and minutes
C
A
B

Publicidad

loading

Este manual también es adecuado para:

Zenit w600 d