WIRING
1. The fans are double insulated and do not need earth wire.
2. For partition fans, precautions must be taken to avoid any back-flow of gases into the room from open flue gas
fire or other appliances.
3. L – connecting to thr Live.
N – connecting tot the Neutral
T – connecting the light live or switched live (for Timer and Hygro units)
ELECTRIC CONNECTION
The(M) must be connected to a monophase network with the tension and Frequency shown on the notice plate of
the fan.The switch connec-tors are situated on the fxing base of the fan.In order to ensure the IP level against water
splash use the appropriate cable junction supplied when placing the connection cable.The fan should be connected,
in a permanent way to a fixed duct through a double wire with a minimum section of 1 mm2 for fixed installation. It
does not need ground connection as it is a fan with double insulation.(class II)