The gapbetween the switch contacts must be no less than 3 mm.
* Switch off the appliance at the installations main switch:
a) if the appliance does not function correctly;
b) before cleaning the outside of the appliance ;
c) if the appliance is not to be used for any length of time.
* The room must have an adequate source of replacement air for this appliance to function effectively. Moreover, if
there is any non­ sealed combustion based appliance such as a water heater, gas stove, etc. in the same room, air
replacement must be suffcient for all appliances to work effectively together.
* The appliance must either exhaust directly to the outside or into a short duct (max 400 mm in length to ensure
certifed performance). Effciency losses will occur if the appliance is installed in ducting subject to any appreciable
back pressure.
* The appliance cannot be used to control activation of water heaters, room heaters, etc. nor must it be connected to
the hot air ducts used by other appliances.
* The air to be extracted from the room must be clean (i.e. free of grease, soot, chemical and corrosive agents, and
explosive or fam­ mable mixtures) and must not exeed a temperature of 40°C.
* Keep the appliances inlet and outlet grilles free to ensure an optimum fow of air.
* Install the appliance so that the impeller is inaccessible from the air­ outlet side as verified by contact with the
Test Finger, in compliance with the current safety regulations. If this is not possible, the relevant protection
accessory must be installed.
* Model (H): do not cover or obstruct the humidity sensor grille.
* Model(M): do not cover the lens of the presence sensor.
NOTICE (For Fan with front shutter items)
1. The shutter operationed by Electric-Thermo Switch automatic open and close .
2. Don 't push the Fan shutter by hand or else tooling.