Descargar Imprimir esta página

Panasonic WV-CL934 Manual De Instrucciones página 18

Ocultar thumbs Ver también para WV-CL934:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Setting of external synchronization switch
When an external synchronizing signal input is provided to the external synchronization input
connector on the rear side of the camera for loop through, select "Hi-Z". To terminate the con-
nector, select "G/L 75 Ω". Select "G/L 75 Ω" for the normal situation, too.
External synchronization switch
External synchronization switch
Important:
• Be sure to turn off the power of each device before connection.
Alarm output
Output specification: Open collector output (exter-
nal max. applied voltage: 16 V DC)
OFF: 2 to 4 V DC, internally pulled up
ON: Output voltage 1 V DC or less (max. drive
current: 100 mA)
Color/black-and-white input
Input specification: No-voltage make contact
input (3 to 5 V DC, internally pulled up)
Color: Open or 3 to 5 V DC
Black and white: Make contact with GND
(required drive current: 0.2 mA or more)
* When color input or black-and-white input is
enabled, set the black-and-white switching, "BW MODE" to "EXT". ( page 40)
* When an external device is connected, exercise care to avoid exceeding the rating.
* Applicable wire: AWG22-AWG28, solid wire/stranded wire
Strip the end 9 to 10 mm of the wire and insert it.
18
All manuals and user guides at all-guides.com
9 to 10 mm
Hi-Z
G /L75
(UP)
NEAR
ABF/MENU
FAR
(SET)
(RIGHT)
(LEFT)
(DOWN)
220 - 240V ~ 50Hz
GEN-LOCK
VIDEO OUT
POEWER
GND
ALARM
OUT
DAY/
GND
NIGHT
IN
GND
ALARM (alarm output)
GND
ALARM
GND
OUT
DAY/
GND
DAY/NIGHT
NIGHT
IN
(color input/BW input)
* The external terminal is the same between
WV-CL930 and WV-CL934.