Notes:
• To clear the registered flaw correction point, move the cursor to the number with which the
target flaw correction point is registered on the "PIX OFF" screen and press the setting but-
ton. The flaw correction positioning screen appears, and then hold down the right and left
buttons for more than 2 seconds simultaneously. The "PIX OFF" screen appears, the flaw
correction point is cleared, and "
• When an auto iris lens with video signal type is used, the flaw correction shall be performed
after darkening the screen.
• The "auto flaw correction function" starts up to automatically detect flaws by moving the
cursor to "RET" on the "PIX OFF" screen and pressing the right and left buttons simultane-
ously. If there are points that seem to be flaws in the dark screen, up to 15 points are auto-
matically detected and registered. In addition, once the "auto flaw correction function" is
activated, all of the registered flaw points are cleared.
Communication configuration [COMMUNICATION]
The required communication configuration is performed to use this unit integrated into the sys-
tem with a receiver.
COAX (RCV):
Uses our receiver (WV-RC100 or WV-RC150).
COAX (default):
Does not use any receiver.
Default restoring [CAMERA RESET]
The settings in the Setup menu are restored to the default settings.
The default settings are restored by moving the cursor to "PUSH SW" of "CAMERA RESET" and
holding down the right, left, and setting buttons for more than 2 seconds simultaneously.
However, the data of the registered flaw correction points is not cleared.
Serial number viewing [SER.NO.]
The serial number of this unit appears.
All manuals and user guides at all-guides.com
" at the right side of the number disappears.
*
49