Gas Connection
x
Thread the appliances pressure regulator with
1/2" male end connection both supplied with this
appliance.
x
Make the gas connection to the inlet of the pres-
sure regulator with 1/2" male pipe threads.
x
Join the pressure regulator to the entrance
threads of the Gas Manifold with gasket supplied
with this appliance. The regulator is marked with a
directional arrow indicating correct direction of gas
flow. Ensure the appliance regulator is installed
with the arrow pointing toward the gas manifold
entrance and make sure the top of the regulator is
facing towards the cabinet front, easily accessible
through the cabinet doors.
x
Connect a manual shut-off valve to the gas supply
in an accessible location for turning on or shutting
off gas to the appliance.
x
Install a coupling between the regulator and the
shutoff valve to complete the connection.
x
Assure all pipe joint connections are gas tight.
x
Check alignment of valves after connecting the
cooktop to the gas supply to be sure the manifold
pipe has not been moved.
A misalignment could cause the valve knob stem
to rub on the control panel, resulting in a gas leak
at the valve.
If an oven is to be installed below this appliance con-
nect gas supply line as shown in figure 10 consider
the below cabinet clearance.
Cooktop Installation Manual
Figure 10.
BURNER BOX
(REAR OF APPLIANCE)
GASKET
FLARE UNION
ADAPTOR
APPLIANCE
PRESSURE
REGULATOR
ALL PIPE JOINTS
1/2" N.P .T.
MANIFOLD
SHUTOFF
VALVES
Figure 11.
ENGLISH
ILLUSTRATIVE GAS SUPPLY PIPING
(NO OTHER APPLIANCE BELOW
COOKTOP)
GAS
012