Burner and nozzle specifications
GB
Table 1
Burner
Reduced Rapid (RR)
Semi Rapid (S)
Auxiliary (A)
Triple Crown (TC)
Supply pressures
*
At 15°C and 1013,25 mbar - dry gas
**
Propane P.C.S. = 50.37 MJ/Kg
***
Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m³
RR
TC
A
PCN 752 T/IX/HA
18
Diameter
Thermal
Thermal
Power
Power
(mm)
kW (p.c.s.*)
kW (p.c.s.*)
Reduced
Nominal
100
0.70
2.60
75
0.40
1.65
55
0.40
1.00
130
1.50
3.30
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
S
S
Liquid Gas
By-pass
Nozzle
Flow*
1/100
1/100
g/h
(mm)
(mm)
***
39
80
189
28
64
120
28
50
73
61
65x2
240
28-30
20
35
Natural Gas
Nozzle
Thermal
Power
1/100
kW (p.c.s.*)
(mm)
**
Nominal
186
2.60
122(H3)
118
1.65
96(Z)
71
1.00
79(6)
236
3.60
103x2
37
20
25
17
45
25
Flow*
l/h
248
157
95
343