EN: Installation Manual
Introduction
The VE735 and VE736 are PIR motion sensors. They have
a patented verified PIR technology.
Installation guidelines
The technology in this detector resists false alarm hazards.
Nevertheless avoid potential causes of instability, such as:
•
Direct sunlight on the detector
•
Heat sources within a field of view
•
Strong draughts onto the detector
•
Large animals in a field of view
•
Obscuring the detector's field of view with large objects,
such as furniture
Install the detector so that the expected movement of an
intruder will be across the fields of view (see example in
Figure 21, item 1). This is the direction best detected by PIR
detectors.
Mounting the detector
1.
Lift off the custom insert (Figure 1).
6 / 48
25
2.
Using a screwdriver, carefully prise open the detector
(Figure 2).
3.
Remove the interior part (Figure 3).
4.
Fix the base to the wall between 1.8 m and 3.0 m (5.9 to
9.8 ft.) from the floor. For flat mounting, use a minimum of
two screws (DIN 7998), at least one in position A and one
in position B. For corner mounting, use screws in positions
SB01
C or D (see Figures 4 and 5).
Note:
pry-off positions are shown in the warning box.
5.
Wire the detector. See Figures 7 and 8.
Note:
Electrical Code, NFPA 70 and CSA C22.1, Canadian
Electrical Code, Part I, Safety Standard for Electrical
Installations.
Figure 16 shows a single detector wiring, Figure 17 —
multiple devices connection.
6.
Select the desired jumper and DIP switch settings (see
"Setting the detector" below).
7.
Replace the interior part (Figure 9).
Align the detector. See "Aligning the beam and walk
8.
testing the detector" on page 7.
9.
Remove the blinders and add the stickers, if required. See
"Selecting the coverage pattern" on page 8 and "Blocking
the curtains" on page 9.
10. Insert the insect-protection caps (Figure 10, item 1).
11. Close the cover (item 2).
12. Replace the custom insert (item 3).
Setting the detector
The detector must be restarted (repowered) after changing the
settings or detection pattern.
Figure 11
(1) J1: PIR sensitivity
(2) Tamper
(3) J3: Dual loop (only available
on VE735)
CP
ST400
Not all screw positions have pry-off tamper. Non
All wiring must be provided according to National
(4) J2: CLM
(5) COM port
(6) PIR DIP switch
P/N 145797999-2 (ML) • REV G • ISS 20DEC18