Warning: If any burner fails to ignite, turn the control knob off (clockwise) and also turn the
cylinder valve off. Wait five minutes before attempting to relight with ignition sequence.
After use, close the gas supply by either turning 'OFF' the switch on the regulator or turning 'OFF' the
cylinder valve.
In the event of light back whilst the appliance is in use. Turn all the controls, cylinder valve and
regulator switch to the 'OFF' position. Wait 5 minutes before attempting to relight the appliance. If the
problem persists after relighting, consult your gas dealer, or the store where you purchased the
plancha, or a qualified gas engineer for assistance or repair. Never try to rectify the problem yourself
as this could result in serious injury and/or property damage.
Clean the appliance of excess fat, before storage, with a damp cloth using a mild detergent solution
as the cleaning agent.
Store the appliance in a clean dry environment.
Do not store your gas cylinder indoors. Store in a well ventilated area away from direct sunlight.
CONNECTING THE GAS CYLINDER TO THE APPLIANCE
This appliance is only suitable for use with low-pressure butane or propane gas and fitted with the
appropriate low-pressure regulator via a flexible hose. The hose should be secured to the regulator
and the appliance with hose clips/nuts. This plancha is set to operate a 28 mbar regulator with butane
gas, and a 37mbar regulator with propane gas, and a regulator with butane/propane mixture at
37mbar, and a regulator with butane/propane mixture at 50mbar and a regulator with butane/propane
mixture at 30mbar. Use a suitable regulator certified to BSEN 16129: 2013. Please consult your LPG
dealer for information regarding a suitable regulator for the gas cylinder.
BEFORE USE PLEASE CHECK FOR LEAKAGE!
Never check for leaks with a naked flame, always use a soapy water solution.
TO CHECK FOR LEAKS
Make 2-3 fluid ounces of leak detecting solution by mixing one part washing up liquid with 3 parts
water.
Ensure the control valve is "OFF".
Connect the regulator to the cylinder and ON/OFF valve to the burner, ensure the connections are
secure then turn ON the gas.
Brush the soapy solution on to the hose and all joints. If bubbles appear you have a leak, which must
be rectified before use.
Retest after fixing the fault. Turn OFF the gas at the cylinder after testing.
If detected leakage can not be rectified, do not attempt to cure leakage but consult your gas dealer.
In the event of gas leakage, turn off the gas supply.