Descargar Imprimir esta página

Bedfont GastroCH4ECK Guia De Inicio Rapido página 3

Ocultar thumbs Ver también para GastroCH4ECK:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6
EN
GastroCH
Taking a mouthpiece breath test
1. Make sure the power cord is connected and the GastroCH
2. Connect the sample line to the direct sample line connector;
3. a click should be audible
4. Attach the mouthpiece to the sample line
5. Press
6.
will be shown onscreen while the sensor is zeroing
7. When prompted by
, inhale and hold breath for the pre-set 15 seconds
8. A beep will sound during the last 3 seconds of the countdown
9. Blow slowly into the mouthpiece, aiming to keep the arrow in the green section
10. The arrow will change colour as the O2 level in the breath sample reduces to the
target 15%, at which point it will turn green and the test will automatically stop
after 3 seconds
11. If you cannot complete the test, press
12. The final results will be shown onscreen
13. Press
for a visual indicator of the results:
= good
= satisfactory
= poor, retake test
14. Press
to return to the results
15. To take another test, press
and then repeat steps 4-13
16. Remove the mouthpiece and sample line in between tests to purge the sensors
with fresh air.
ECK
®
4
ECK® is switched on
4
PAGE 4
Collect a breath bag sample
1. Remove the blue plugs from the breath bag
2. Place two clamps on the inlet and outlet but leave them open
3. Attach a mouthpiece to the inlet
4. Exhale gently into the bag until your lungs are nearly empty
5. When your lungs are nearly empty, close the clamp at the outlet
6. Fill the bag and then close the clamp at the inlet
7. Replace the blue plugs
8. To take multiple breath bag samples, repeat steps 1-7 with new breath bags.
Analyse breath bag sample
1. Make sure the power cord is connected and the GastroCH
2. Attach the moisture filter to the bag sample connector
3. Press
4. Remove the blue plug from one end of the breath bag and attach to the moisture
filter. Open the clamp on the inlet of the breath bag
5. Press
to begin breath bag sampling
6.
will be shown onscreen while the sensor is zeroing
7. Once zeroed, the GastroCH
ECK® will automatically begin bag sampling for 45
4
seconds as indicated by
make sure that the clamp is open
8. The final results will be shown onscreen
9. Press
for a visual indicator of the results:
= good
= satisfactory
= poor, retake test
10. Press
to return to the results
11. To take another test, press
and then repeat steps 3-10.
ECK® is switched on
4
PAGE 5
EN

Publicidad

loading

Productos relacionados para Bedfont GastroCH4ECK

Este manual también es adecuado para:

Gastrolyzer