1. Transport machine to a flat, dry surface in a well--
ventilated area for charging.
WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
2. Turn all switches to the OFF position and remove
key if equipped. Set parking brake, if equipped.
3. Unlatch and hinge open both the dust bag hood
and the battery hood to access the battery
compartment.
4. Before charging the batteries, check the
electrolyte level in each battery cell (Figure 22).
FOR SAFETY: When servicing machine, wear
protective gloves and eye protection when
handling batteries and battery cables. Avoid
contact with battery acid.
The electrolyte level (A) should slightly cover the
battery plates (B). Add distilled water as needed.
DO NOT OVERFILL, the fluid may expand and
overflow while charging. Replace cell caps before
charging (Figure 23).
A
B
5. Connect the charger's AC power supply cord to a
properly grounded receptacle (Figure 24).
Nobles SpeedGleam/Plus (01- -05)
FIG. 22
FIG. 23
Grounded
3 Hole Outlet
Ground Pin
6. Connect battery charger into machine as shown.
Flip up hood support stand and rest hood on stand
to promote ventilation (Figure 25).
FIG. 25
7. The charger will automatically begin charging and
shut off when fully charged.
ATTENTION: Do not disconnect the charger's DC
cord from the machine's receptacle when the
charger is operating. Arcing may result. If the
charger must be interrupted during charging,
disconnect the AC power supply cord first.
WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
8. After charging, check the electrolyte level (A)
again. The level should be approximately 1 cm
from the bottom of the fill--port (B) (Figure 26).
Add distilled water if needed. DO NOT OVERFILL.
B
A
OPERATION
FIG. 24
FIG. 26
13