TROUBLESHOOTING
PROBLEM
The burner will not
light with a match.
No gas flow or an
obstructed gas flow.
Excessive
flare-ups.
All manuals and user guides at all-guides.com
POSSIBLE CAUSE
1. Match not reaching burners
(when holding match with hand).
2. Empty tank.
3. Poor connection between valve
regulator and LP cylinder
coupling.
4. Burner inlet blocked.
1. Tank valve not on or fully opened.
2. Empty tank.
3. Poor connection between valve
regulator and LP cylinder
coupling.
4. Burner inlet blocked.
1. Grease and/or residue build-up
on heat tents or in firebox.
2. Excessive dripping of fat or
marinade from food.
3. Cooking temperature too high.
CORRECTIVE ACTION
1. Use match holder found in
cabinet door.
2. Check fuel level and refill tank if
necessary.
3. Turn off grill knobs, close the LP
cylinder valve at top of cylinder
and check the connection
between the regulator valve
and cylinder coupling.
Disconnect and reconnect, if
necessary.
4. Clean the burner inlet (venturi)
and burner as described by the
Care and Maintenance section
in the manual.
1. Fully open tank valve by turning
counterclockwise.
2. Check fuel level and replace
fuel if necessary.
3. Turn off grill knobs, close the LP
cylinder valve at top of cylinder
and check the connection
between the regulator valve
and cylinder coupling.
Disconnect and reconnect, if
necessary.
4. Clean the burner inlet (venturi)
and burner as described by the
Care and Maintenance section
in the manual.
1. Clean the grill components.
2. Trim the fat from meat and use
non-oil based marinades.
3. Lower temperature accordingly.