Press the SET button again to display the current value. Press UP or DOWN to scroll and choose the type of functionality.
C0 = The STEP BY STEP command performs the sequential functions: "open-stop-close-open-......".
When the door is fully opened, the automatic reclosing occurs only if parameter P4 is different from b0.
C1 = With the door closed, activation of STEP BY STEP opens.
During the opening, activation of STEP BY STEP is ignored (it has no effect, the door continues to open).
When the door is fully opened, STEP BY STEP activation closes. If the door is fully opened and automatic re-closing is enabled (a value different
from "b0" has been set for parameter P4), the door closes again after the time set by the value "b1...b9" has elapsed.
If the STEP BY STEP command is activated during the closing, the door opens.
When the door is fully opened, the automatic reclosing occurs only if parameter P4 is different from b0.
C0
C2 = With the door closed, activation of STEP BY STEP opens.
C1
During the opening, activation of STEP BY STEP is ignored (it has no effect, the door keeps opening).
C2
If automatic reclosing has been enabled (a value different from "b0" has been set for parameter P4), with the door fully open, activation of STEP
BY STEP restores the pause time count (it restarts counting as if the door had just reached the fully open position).
If automatic reclosing has NOT been enabled (and therefore the value "b0" has been set for parameter P4), with the door fully open, activation
of STEP BY STEP has no effect: the door remains opened.
WARNING: in this case the door remains always opened, therefore in order to avoid this condition remember to set a value other than "b0" in
the parameter P4.
If the STEP BY STEP command is activated during closing, the door opens.
When the door is fully opened, the automatic reclosing occurs only if parameter P4 is different from b0.
C0 Press SET to confirm. The default setting is "C0".
Maintenance alarm
P1 Press and hold the SET button, the display shows "P1".
P7 Press the UP button six times to display "P7".
00
Press the SET button again to display the current value. Press UP or DOWN to scroll and choose the type of maintenance.
05
10
00
15
no active maintenance
...
45
00 Press SET to confirm. The default setting is "00". When the number of cycles is reached, the LED lights flash for 2 minutes.
Cycle counting
P1 Press and hold the SET button, the display shows "P1".
P8 Press the UP button seven times to display "P8".
Press the SET button again to display the current value. Press UP or DOWN to display the engine cycle counter:
the 6-digit number is displayed two digits at a time and between one number and the next the display remains off for 1 second.
Ex. 10 --> 20 --> 30 = 102030 engine cycles
00 Press SET to exit.
Activation of minimum opening for air recirculation
Attention: to activate air recirculation, save the function as shown below
P1 Press and hold the SET button, the display shows "P1".
p9 Press the UP button eight times to display "P9".
R0
Press the SET button again to display the current value. Press UP or DOWN to scroll and choose the type of opening
R1
r0
R2
...
deactivated
R6
Press SET to confirm. The default setting is "R0". Opening for air recirculation is activated by pressing the first button (CHA) of the radio control
R0
and closing with the second button (CHB) of the radio control.
SCENARIO 1 - CON RICICLO D'ARIA ABILITATO
SCENARIO 1 - WITH AIR RECIRCULATION ENABLED
CHA = APERTURA
RICICLO D'ARIA
AIR RECIRCULATION OPENING
Cancellation of the travel
p1 Press and hold the SET button, until "P1" is displayed "P1".
0p Press and hold the SET button, until "OP" is displayed
CL Press and hold the SET button, until "CL" is displayed.
L Press and hold the SET button, "L" flashes. Reset travel.
p
1
.
x6 s
24
05
maintenance is activated at
5000 cicli
r1
r2
~ 4-5 cm
~ 8-10 cm
CHB = APERTURA / CHIUSURA PORTONE
OPENING / CLOSING DOOR
+
CHIUSURA RICICLO D'ARIA
AIR RECIRCULATION CLOSING
0
.
10
maintenance is activated at
maintenance is activated at
10000 cicli
15000 cicli
r3
~ 12-15 cm
SCENARIO 2 - CON RICICLO D'ARIA DISABILITATO
SCENARIO 2 - WITH AIR RECIRCULATION DISABLED
p
.
.
15
...
... maintenance is activated at
45000 cicli
r4
r5
~ 16-19 cm
~ 20-23 cm
CHB = APERTURA / CHIUSURA PORTONE
OPENING / CLOSING DOOR
C
L
.
.
45
r6
~ 24-30 cm