NOTE: If engine is warm or the temperature is above
50˚F, move the choke lever right RUN position.
To turn the engine on, push in at the top of the switch.
To start the engine, push down and continue to push in
on the lock button.
Release the switch when the engine starts.
NOTE: The battery may require charging before the gen-
erator can be started using only the engine switch. The
generator can be started by pulling the recoil starter grip.
Once the generator is started, the battery will charge as
the unit runs.
To start the engine manually, leave the switch in the ON
( l ) position and pull the recoil starter grip until the engine
runs.
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place.
Allow the engine to run for 15-30 seconds, then move
the choke lever right to the RUN position.
Normal maintenance, replacement or repair of emission con-
trol devices and systems may be performed by any qualified
repair establishment or individual with original or equivalent
parts. Warranty and recall repairs must be performed by an
authorized service center; please contact customer service
for assistance.
WARNING:
When servicing, use only recommended or equivalent
replacement parts. Service or maintenance performed
by unqualified personnel or use of any other parts could
result in a personal injury hazard or property damage.
WARNING:
Before inspecting, cleaning or servicing the machine, shut
off engine, wait for all moving parts to stop, and discon-
nect spark plug wire and move it away from spark plug.
Allow 30 minutes of cool down time before performing
any maintenance. Failure to follow these instructions
can result in serious personal injury or property damage.
NOTICE:
Periodically inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts,
caps, etc. Tighten securely all fasteners and caps and
do not operate this product until all missing or damaged
parts are replaced. Please contact customer service or
a qualifed service center for assistance.
OPERATION
STOPPING THE ENGINE
See Figures 12 and 14.
To stop the engine under normal operating conditions:
Remove any load from the generator.
Turn the fuel valve to the OFF ( O ) position.
To stop the engine, push in at the bottom of the switch
to place the engine switch in the OFF ( O ) position.
To stop the engine in an emergency situation:
Put the engine switch in the OFF ( O ) position.
While operating and storing, keep at least 3 feet of clear-
ance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of "cool down" time
before storage. Heat created by muffler and exhaust
gases could be hot enough to cause serious burns and/
or ignite combustible objects.
MAINTENANCE
GENERAL MAINTENANCE
Keep the generator in a clean and dry environment where it
is not exposed to dust, dirt, moisture, or corrosive vapors.
Do not allow the cooling air slots in the generator to become
clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water en-
tering the fuel system or other internal parts of the unit can
cause problems that will decrease the life of the generator.
To clean the unit:
Use a soft bristle brush and/or vacuum cleaner to loosen
and remove dirt and debris.
Clean air vents with low pressure air that does not exceed
25 psi.
Wipe the exterior surfaces of the generator with a damp
cloth.
CHECKING/CLEANING AIR FILTER
See Figure 15.
For proper performance and long life, keep air filter clean.
Release latches on the air filter cover. Remove cover and
set aside.
Remove the filter element.
If the filter element is dirty, clean with warm, soapy water.
Rinse and let dry.
Apply a light coat of engine lubricant to the element, then
squeeze it out.
Page 15 — English
WARNING: