TROUBLESHOOTING
PROBLEM
• There is no spark when lighting
the gas
• The gas ring burns unevenly
INSTRUCTIONS FOR THE INSTALLER
Overall dimensions
Width: 700mm
Depth: 510mm
Cut out dimensions
Width: 560mm
Depth: 480mm
TECHNICAL DATA
Burner configuration
Triple Flame (Wok)
Rapid burner
Semi rapid burner (Medium)
Semi rapid burner (Medium)
Auxiliary burner (Small)
CORRECTIVE ACTION
• Check that the unit is plugged in and the electrical
supply is switched on
• Check that the RCCB has not tripped (if fitted)
• Check the mains fuse has not blown
• Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
• Check the main jet is not blocked and the burner
crown is clear of food particles.
• Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
LPG I
(28~30/37)
3+
Injector Dia.
kW
(mm)
0.94
3.5
0,87
3.0
0.65
1.75
0.65
1.75
0.51
1.0
-27-
NG (20)
Injector
kW
Dia. (mm)
1.31
3.5
1.29
3.0
0.97
1.75
0.97
1.75
0.76
1.0