mm) in order to detect the presence of the test parallelepiped (B) (height: 700 mm) positioned as shown in F11 on Page 33.
Note. The presence detection test sample is a parallelepiped with 3 sides with light-coloured reflecting surfaces and 3 sides with
dark-coloured, opaque surfaces.
In order to further reduce the risk of impact with the gate wing in the opening area, an extra pair of photocells (C) (recommen-
ded height: 500 mm) can be installed for the detection of the presence of the test parallelepiped (D) (height: 700 mm) positioned
as shown in F11 on Page 33.
"EXAMPLE OF TYPICAL INSTALLATION" picture
1
2
Type of control
Person-present control
Pulse control with the gate in
sight
Pulse control with the gate
not in sight
Automatic control
(i.e. control with
timed closing)
Remember that anyone who sells and/or motorises doors/gates becomes the manufacturer of the automatic door/gate
machine and must therefore prepare and conserve a technical folder that contains the following documents (see Machinery
Directive Enclosure V):
• Assembly drawing of the automatic door/gate;
• Electrical connection and control circuit wiring diagram;
• Risk analysis including: a list of the essential safety requirements provided in Machinery Directive Enclosure I; a list of the risks
posed by the door/gate and the description of the solutions adopted.
• Keep these operating instructions in a safe place together with the instructions for all the other components;
• Prepare these operating instructions and general safety warnings (for the completion of these operating instructions) and
deliver a copy to the final user;
• Fill out the maintenance register and deliver a copy to the final user;
• Fill out the or plate and apply it to the door/gate.
Note: The technical folder must be conserved for inspection by the competent national authorities for at least ten years from
the date construction of the automatic door/gate.
Operating instructions and warnings
3
4
5
"OPERATING CONTROL" table
Informed users
(private areas)
Pushbutton control
Pushbutton control with key
Force limitation
or
presence detectors
Force limitation
or
presence detectors
Force limitation
and photocells
or presence detectors
RESPONSIBILITIES OF THE INSTALLER
6
7
8
9
Type of use
Informed users
(public areas)
The person-present control is
Force limitation
or
presence detectors
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
L I V I 5 0 0
Pos.
Description
1
102 Lux key selector
2
Remote-control
3
Safety edge
104 Lux series
4
photocells
Electric lock
5
1Pilly 60 column
6
LIVI 503R
7
Lumy flashing light
8
Control box
9
Uninformed users
not possible
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
11