Descargar Imprimir esta página

Dometic TEC29LPG Instrucciones De Montaje página 21

Ocultar thumbs Ver también para TEC29LPG:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 69
TEC29, TEC29LPG
9.4
TEC29 only: installing the tank and fuel supply line
Please observe the following instructions for the installation location:
• The tank bottom must be positioned at a maximum of 0.3 m below the bottom of
the generator.
• The top of the tank must not be higher than the top of the generator.
➤ Lay the fuel line as straight as possible.
➤ Secure the tank, see fig. 0, page 5 and chapter "TEC29 only: connecting the
float" on page 29.
9.5
TEC29LPG only: connecting the gas supply
The generator is connected to the low pressure regulator (30 millibar) of the LPG
cylinder.
➤ Lay the gas line using a suitable metal pipe.
➤ Connect the gas line as shown in fig. a, page 6.
9.6
Mounting the remote control
Please observe the following instructions for the installation location:
• Observe the length of the extension cable from the remote control to the
generator.
➤ Drill the holes as shown in fig. b, page 6.
➤ Insert the plug into the remote control.
➤ Screw on the remote control.
EN
Installation
21

Publicidad

loading

Este manual también es adecuado para:

Tec29