Technical data Wood's WCD6HG
Maximum working area
Recommended working area
Air flow
Capacity at 20ºC & 70% RH
Capacity at 30ºC & 80% RH
Power at 20°C & 70% RH
Power at 30°C & 80% RH
Sound level
Working interval temperature
Fan speeds
Dims, LxWxH
Weight
Cooling media
IP rating
Trouble shooting
If you are having trouble with your dehumidifier, please refer to below trouble shooting. If nothing of the below works,
please contact your retailer for servicing of your dehumidifier.
Trouble
The dehumidifier doesn't
work
The unit doesn't start
No air inlet
Abnormal noise
Trouble code: E1
Trouble code: E2
Trouble code: E4
English
Cause
Is the power cord connected?
Is the room temperature over 40°C or below
0°C?
The dehumidifier stops operating when the
set humidity is 2% higher than the ambient
humidity
Is the filter blocked?
Is the air inlet or air outlet jammed?
Is the filter blocked?
Is the unit inclined?
Is the filter blocked?
When the display shows E1, there is a pro-
blem with temperature sensor or the connec-
tion wire is not properly fixed
When the display shows E2, there is a pro-
blem with humidity sensor or the connection
wire is not properly fixed
When the display shows E4, there is a pro-
blem with the water pump
570 m
2
10-315 m
2
1000 m
/h
3
33 litres
88 litres
862 W
1260 W
60 dB
0°C to +40°C
1
635x500x800 mm
53 kg
R410 A (780 g)
IP21 (X1)
Solution
Connect the unit to a power outlet
Increase or decrease room tempe-
rature
To save energy, set the humidity level
higher
Clean the filter
Clear the blockage
Clean the filter
Move the unit to a flat and solid
ground
Clean the filter
Contact your retailer
Contact your retailer
Contact your retailer
6