Gas connection
This appliance must be installed and connected in accordance with installation
regulations in force in the country in which the appliance is to be used.
This appliance is supplied to run on LPG and natural gas. Conversion for
use on LPG and natural gases must only be undertaken by a qualified person.
Gas supply replacement and installation guidelines:
LPG > NG
It is the law that all gas appliances are installed by competent persons in
accordance with the current edition of the Gas Safety Installation and
Use Regulations .
It is in your interest and that of safety to ensure compliance with the law.
Gas adjustment
• Take precautions on the operations and adjustments to be carried out when
converting from one gas to another.
• All work must be carried out by a qualified technician.
• Before you begin, turn off the gas and electricity supply to the appliance.
1 Change the injector of the burners
Remove the pan support, Burner lid and Flame spreader.
Unscrew the injector using a 7mm box spanner and
replace it with the stipulated injector for new gas
supply. Carefully reassemble the all components.
After injectors are replaced, it is advisable to strongly
tighten the injector in place.
Injector
The gas rail
seal
G1/2"Female coupler
NG > LPG
The gas rail
seal
Ø11.5 Female coupler