Sl4018
14
opERATING ThE Tool
TESTING ThE Tool
1
Disconnect air hose from the tool.
Remove all fasteners from the tool.
ALL SCREWS MUST BE TIGHTENED.
If any screws are loose, tighten them.
ThE SAfETY/pUSh lEVER AND TRIGGER MUST
MoVE SMooThlY.
Adjust the air pressure to 70psi.
Connect the air hose.
Do not load any fasteners in the tool.
ThE Tool MUST NoT lEAK AIR.
Remove finger from the trigger and press the safety/
push lever against the wood.
ThE Tool MUST NoT opERATE.
2
Separate the safety/push lever from the wood.
Next, point the tool in a safe position, pull the trigger and
then hold that position for 5 seconds or longer.
ThE Tool MUST NoT opERATE.
Without touching the trigger, depress the safety/push
lever against the work piece.
1
Pull the trigger.
ThE Tool MUST opERATE If SET IN SEQUENTIAl
fIRE MoDE.
Hold the trigger back while separating the safety/push
lever from the wood.
2
Remove finger from the trigger.
Tool opERATIoN WIll END.
(the driver blade will return to the top).
With the tool off the work piece, pull the trigger.
Depress the safety/push lever against the work piece.
ThE Tool MUST opERATE If SET IN bUMp fIRE
MoDE.