... the appliance fails to
cool the air properly ...
... the appliance makes a lot
of noise ...
... the appliance is switched
on but the compressor is
not running ...
46
Make sure that the fast connection is fitted
properly.
In the event of the indication "F3" appearing on
the display screen, proceed as follows:
1° Disconnect the appliance from the power
supply and connect it up again.
2° Check which mode the appliance is set to
(heating/cold mode).
3° Check that the appliance heats / cools
properly depending on the mode it is set to.
4° If the problem persists, get in touch with our
Official Technical Service.
Ensure that the window or the door is open as
little as possible. This is especially important if
the window or door has to be opened slightly for
the connection hose.
Check that the connection hose is not restricted -
it must not be crushed.
Check that the air inlet and outlet are not
blocked.
If you hear a cyclical water noise, the
condensate pump is pumping the water oufside.
If the outdoor motor makes a repetitive noise,
remove the plug from the outdoor unit.
The delayed start system is activated each time
that the appliance is turned on. The appliance
comes on audibly after three minutes.
Should the "dehumidification" light flash, then the
dehumidification function
with a room temperature of less than 18°C. The
compressor turns itself off (see
recommendations and warnings in the
"Dehumidification only" section).
The ambient temperature must be above 18°C
for the appliance to operate in dehumification
and cooling mode.
Should "F1" or "F2" appear on the display
screen, then a fault has occurred in the thermal
probes. Inform the brand's Official Technical
Assistance Service!
has been selected