The Set-Up Menu - Castolin Eutectic POWER max Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

The set-up menu

Adjust the following parameters within the set-up menu
- Arc force (for the rod-electrode welding process)
- Characteristic (for the rod-electrode welding process with
CEL electrodes)
Function principle
The parameters are a 4-stage setting
The numbers of indicators that have lit up correspond to the
setting value (stage).
Indicators light up:
None
One
Two
Three
Example: if three indicators are lit
up, the setting is on Stage 3
Stage 3
Fig.9
Example of stage indication
Setting the parameters
The following example of how to set a parameter is for the rod-
electrode welding process, as illustrated by the arc-force para-
meter.
- Select the rod-electrode welding process
holding the process changeover switch
- The pre-set stage is indicated for 1 second
As long as you hold the process changeover switch
force parameter will be increased by one stage per second.
- As soon as the desired stage is indicated
- Release the process changeover switch
- The setting-value (stage) for the arc-force parameter is
stored
- The rod-electrode welding process is indicated
N.B.! Even if you unplug the machine from the mains, the
selected parameters will still be stored.
"Arc force" parameter (for the rod-electrode
welding process)
The arc-force parameter is for influencing the short-circuiting
amperage at the instant of droplet transfer.
If there are problems with rod electrodes tending to "stick", set
the arc-force parameter to a higher value.
Stage 0 ..... Soft, low-spatter arc
Stage 3 ..... Harder, more stable arc
Setting
Stage 0
Stage 1
Stage 2
Stage 3
U (V)
Fig.10
by shifting and
, the arc-
19
40 A (factory setting)
27 A
13 A
0 A (no LED)
Pre-set welding current Schweißstrom
Rod-electrode welding: Arc-force parameter setting
Stufe
0
1
2
3
I (A)
+13A +27A +40A