These units are powered by air-cooled four cycle engines
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
and designed to run at maximun 3750 RPM and give a
continuous wattage as rated. On these models, a low-oil
level shutoff is provided to protect the engine. This feature
is usually associated with extended run models.
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
When unpacking, inspect carefully for any damage that may
have occurred during transit. Make sure any loose fittings,
bolts etc., are tightened before putting unit into service.
Report any missing items at local distributor
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.

GENERAL SAFETY

PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
Before starting or servicing any generator, read and
1
understand all instructions. Failure to follow safety
precautions or instructions can cause equipment damage
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.
or serious personal injury or death. Engine instructions for
these units are contained in a separate manual. Retain
all manuals for future reference.
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
Never use this generator for any aplication other than
2
that specified by the manufacturer. Never operate
this generator under conditions not approved by the
manufacturer. Never attempt to modify this generator to
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.
perform any manner not intended by the manufacturer.
For maintenance and repairs, use only products and
3
parts recommended by the manufacturer.
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
Be sure that the generator is properly grounded to an
4
external ground path prior to operation. Refer to the
section entitled:
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.
grounding procedures.
Be sure that the generator is operated only by persons
5
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
who have read and understand these instructions.
Be sure that the generator is placed on a flat level
6
surface to prior and during the operation. The generator
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.
must not slide or shift during operation.
Do not operate the generator on wet surfaces or
in the rain.
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
7
Keep all persons away from the generator during
operation.
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.
Do not allow persons wearing loose clothing or jewelry to
8
start or operate the generator. Loose clothing or jewelry
may become entangled in moving components, causing
equipment damage and or personal injury.
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
Keep all persons away from parts that move or become
9
hot during operation.
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.
Be sure all powered devices are shut off prior to conecting
10
them to the generator.
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
11
Keep the generator clean and well maintained at all
times.
12
Be sure that all tools and appliances are in good repair
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.
and are properly grounded. Use devices that have three
prong power cords. If an extention cord is used, be sure
that it has three prongs for proper grounding.
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO
DESCRIPTION
UNPACKING
Grounding instruction for proper
Never use the generator if is damaged or has loose
13
fittings, bolts etc.
14
Use only unleaded fuel. Do not refill the fuel tank while
the engine is running. Use precautions to prevent fuel
spillage during refills. Be sure the fuel tank cap is securely
in place before starting the engine. Allow engine to cool
for at least two minutes before refueling.
15
Store fuel in a safe container in a well ventilated area,
away from open flames.
Never operate the generator in an explosive
or flammable atmosphere or poorly
ventilated area.
Shut off the engine and disconnect the spark plug
wire before performing any service maintenance to
the unit.

BEFORE STARTING

Check the fuel level before starting your generator. For
1
best result use only regular grade unleaded gasoline
(minimum 90 octanes).
Always use unleaded fuel, it produces less
remainders in the spark plug, prolonging the life
of the exhaust system.
octane can cause persistent noise, and damage to
the engine, if some of these occurs while running
in constant speed under a normal charging load,
change quality of fuel, occasionally your generator
can make some noise while it operates under high
charge of load. This is not important, simply means
that the generator is working efficiently.
2
Verify the level of the oil of the engine before starting your
generator, the level of the oil must be between the mark
of low and high level of the dipstick.
This product is send by manufacturer without oil.
The oil is very important in the engine
performance.
Oils with detergents and vegetal
oils are not recommended. Do not add commercial
additives to the recommended oil and don't mix oil
with gasoline. SAE 10W-30 is recommended for
general use, other viscosities shown in the illustration
can be used when the average temperature in their
area is within the indicated rank.
Using gasoline of low