Schedule to EU-Type Examination Certificate No. TÜV 99 ATEX 1496 X
VISY-Stick ... RS485; VISY-Stick (Flex) Temp RS485; TORRIX Ex ...;TORRIX Ex C...;
TORRIX Ex RS485...; TORRIX Ex TAG...; TORRIX Ex XT...; VISY-Stick ... Advanced RS485;
VISY-Stick ... Flex RS485; TORRIX Ex ...-A; TORRIX Ex ... Flex; TORRIX Ex ... PL;
TORRIX Ex C...-A; TORRIX Ex C... Flex; TORRIX Ex C... PL; TORRIX Ex RS485...-A;
TORRIX Ex RS485... Flex; TORRIX Ex RS485... PL; TORRIX Ex TAG...-A;
TORRIX Ex TAG... Flex; TORRIX Ex TAG... PL; TORRIX Ex XT...-A; TORRIX Ex XT... Flex
and TORRIX Ex XT... PL:
For EPL Ga or EPL Ga/Gb or EPL Gb, the permissible temperature range depending on the
variant and the temperature class can be taken from the following table:
Temperature class
T6
T5
T4
T3
T2
T1
For EPL Db applications, the permissible ambient temperature range depending on the
permissible surface temperature can be taken from the following table:
Dust layer ≤ 5 mm
T
X°C
5
I
≤ 100 mA: X°C = T
i
I
≤ 200 mA: X°C = T
i
The equipment is suitable for dusts with an ignition temperature of more than 200 °C under a
dust layer of 5 mm (glow temperature).
P17-F-011
Ambient temperature range
I
≤ 100 mA: -40 °C ... +40 °C
i
I
≤ 200 mA: -40 °C ... +25 °C
i
I
≤ 100 mA: -40 °C ... +55 °C
i
I
≤ 200 mA: -40 °C ... +40 °C
i
I
≤ 100 mA: -40 °C ... +85 °C
i
I
≤ 200 mA: -40 °C ... +70 °C
i
I
≤ 100 mA: -40 °C ... +85 °C
i
I
≤ 200 mA: -40 °C ... +70 °C
i
I
≤ 100 mA: -40 °C ... +85 °C
i
I
≤ 200 mA: -40 °C ... +70 °C
i
I
≤ 100 mA: -40 °C ... +85 °C
i
I
≤ 200 mA: -40 °C ... +70 °C
i
Maximum surface temperature
+ 40 °C
Observe EN 60079-14
a
+ 55 °C
Observe EN 60079-14
a
This certificate may only be reproduced without any change, schedule included.
Excerpts or changes shall be allowed by the TÜV NORD CERT GmbH
Rev. 02/11.21
With total immersion
T X°C
Issue 03
Medium temperature range
-40 °C ... +75 °C
-40 °C ... +90 °C
-40 °C ... +125 °C
-40 °C ... +190 °C
-40 °C ... +285 °C
-40 °C ... +435 °C
Ambient temperature range
T
a
-40 °C ... +85 °C
-40 °C ... +70 °C
Page 6/8