LEAK CHECK PREPARATION
Check That All Burner Valves Are Off
Valves are shipped in the OFF position, but you should check to be sure that they are
turned off . Check by pushing in and turning clockwise . If they do not turn, they are off . If
they do turn continue turning them clockwise until they stop, then they are off .
m WARNING: The gas connections of your Summit
have been factory tested. We do however recommend that
you leak check all gas connections before operating your
Summit
Gas Grill.
®
Remove Control Panel
Tools needed: Screwdriver, pliers, and towels .
A) Remove burner control knobs (1) .
B) Open both doors . With a screwdriver, remove screws from the underside of control
panel (2) .
C) Lift and remove battery housing located inside grill cabinet (3) .
D) Using needle-nose pliers, disconnect wire terminals from the top of battery housing
(4) . Do not pull on the wires; remove them by pulling on the wire terminals.
E) Place towels on the tops of both door assemblies .
This will protect control panel and door assemblies from getting scratched on
next step.
F) Tilt bottom of control panel forward . Lift slightly (5) and then rotate it face down to
rest on tops of door assemblies . (Be careful not to break or disconnect wires for the
control panel LEDs .)
G) Carefully pull battery wires out from the inside of the grill cabinet (6) .
H) Fully open right door . Place control panel on floor, leaning against towel covering
right door assembly (7) .
◆
10
GAS INSTRUCTIONS
Gas Grill
®
4
1
3
7
2
5
6
The grills illustrated
in this Owner's Guide
may vary slightly from
the model purchased .