Standby time
After a certain time, the appliance
reduces the soldering tempera-
ture to save power.
Default value: 5 min.
Value range:
0 to 60 min.
0 = Off
A
Hold down both keys for a
prolonged period to open the
standby time menu.
B
Adjust standby time by press-
ing the keys (0 = Off).
C
Wait five seconds to save the
value.
Error codes
In the event of an error, an error
code appears on the display. The
number above the label 'Err'
provides information about the
error present.
Codes 7 and 8 indicate faults
in the heating element in the
soldering iron:
- Err7 Insert heating element
and press key.
- Err8 Change heating
element
For further information, go to the
following link:
nano.ersa.com
10
English
|
Soldering iron
If required, the soldering iron
can be changed or exchanged.
Use only soldering irons bearing
the description Ersa i-TOOL NANO.
Installation of the exchange iron
is by analogy the reverse of the
dismantling sequence.
A
Turn appliance onto its side.
B
Pull cable of soldering iron
out of holders.
C
Remove plug in the direction
of the operating panel.
Technical specifications
i-CON NANO soldering station:
Power rating:
Operating voltage:
Temperature range:
Dimensions L x W x H:
Weight:
i-TOOL NANO soldering iron:
Dimensions:
Weight:
Holder stand:
Dimensions L x W x H:
Weight:
SD card
Using a micro SD card will per-
mit further settings to be made
via software:
- Standby temperature & time
- Shutdown time
- Keylock function
- Display in °C or °F
- Up to 3 fixed temperatures
- Power functions can be as-
signed
For further information on using
the micro SD (HC) card, please
consult the software manual.
Both software and the manual
can be downloaded free by going
to the following link:
nano.ersa.com
Order no.: 0IC1205A
68 watts
220 - 240 V ~ 50/60 Hz
110 - 120 V ~ 50/60 Hz
150 - 450 °C / 300 - 842 °F
145 mm x 80 mm x 103 mm
1050 g
Order No.: 0125CDK
ø
L x handle-
/ 175 mm x 15 mm
30 g (without cable)
Order No.: 0A59
140 mm x 80 mm x 80 mm
200 g