Electrical connection
•
Electrical connection must be made before connecting the appliance to
the electricity supply.
•
Installation must be carried out by qualified personnel who know the
current safety and installation regulations. Specifically, installation must
be carried out in compliance with the regulations of the local electricity
supply company.
•
Make sure the voltage specified on the data plate located on the bottom
of the appliance is the same as that of the home.
•
Regulations require that the appliance be earthed: use conductors
(including the earth conductor) of the appropriate size only
Connection to the therminal block:
For the electrical connection, use an H05 VV-F3G 4mm²
ATTENTION:
the power supply cable must be long enough to allow the
cooktop to be removed from the worktop and must be positioned to avoid
damage or overheating caused by contact with the base.
220-240V~50/60Hz
H05 VV-F 3G 4 mm²
11
Neutral
Neutre
Earth
Terre
Erdung