SMOKE EXHAUST
NANCY is design to have the smoke exhaust pipe connected to the top, the back or the right side.
The stove is supplied already set up for a top-connecting smoke exhaust pipe.
CONNECTING THE SMOKE EXHAUST PIPE ON THE TOP
To complete connection simply fi t a stainless steel chimney fl ue with an 8 cm diameter (not supplied) on the elbow joint (G fi g.5)
which is already mounted on the stove and accessible by opening the right glass door (fi g. 5).
NOTE: An inspection lid for cleaning (H) is located on the elbow joint (G).
In this case you must use the pre-cut lid provided separately (C - fi g. 1 on pg. 27), removing the diaphragm C2, instead of the
uncut lid supplied.
N.B.: Seal the elbow to the fl ue pipe using the high temperature silicone supplied
CONNECTING THE SMOKE EXHAUST PIPE ON THE BACK
• Loosen the locking clamp (F-fi g. 5) of the elbow joint and rotate it by 90 degrees.
• Connect the stainless steel chimney fl ue with an 8 cm diameter, passing it through the pre-cut hole on the lower part of the sheet
metal back
N.B.: Seal the elbow to the fl ue pipe using the high temperature silicone supplied
CONNECTING THE SMOKE EXHAUST PIPE ON THE SIDE
• Remove the elbow joint (G - fi g.6)
• Remove the cast iron cap on the lower part of the side.
• Remove the pre-cut diaphragm on the metal support inside the hole of the cast iron cap
• Fit the stainless steel chimney fl ue with an 8cm diameter on the connecting sleeve (F - fi g. 7) passing it through the cast iron hole.
• In this case the cast iron cap is not longer used.
• The elbow (G) can be used externally to collect condensation.
F G
fi g. 5
AIR INTAKE
An air intake duct connected to the outside with a minimum diameter of 80 cm² must be pre-set on the back of stove in order to
guarantee suffi cient air supply to the stove for combustion.
A hole (U - fi g. 9) is pre-set on the back of the stove for attaching the duct.
Open the left front door (fi g. 8), detach the fl exible pipe (T) from its support (S) and push it through the hole (U) on the back of
the stove.
Connect the external air intake duct to the hole until reaching the outdoors.
The external air intake duct must be less than 1 metre in length, have no bends and must end with a 90° downwards section or a
wind guard.