BFT BOTTICELLI VENERE Instrucciones De Uso Y De Instalacion página 14

Ocultar thumbs Ver también para BOTTICELLI VENERE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 21
4) Bring the leaf to the required opening position, using the "UP" and "DOWN"
buttons on the control unit, and keeping in mind that the "DOWN" button
closes the leaf, while the "UP" button opens the leaf.
5) As soon as the leaf reaches the required opening position, press the "OK"
button in order to memorise the limit device opening position. The "SET" led
confirms data storage by blinking for 1 second and then lits up again.
6) Correctly position the "carriage lock" against the carriage (fig.18 ref.6 A-B).
NOTE 1: These manoeuvres are carried out in "hold-to-run" mode at reduced
speed and with no safety devices activated.
NOTE 2: In case of errors, the "SET" led remains off on for 5 seconds.
9) OPENING / CLOSING TORQUE AUTOSETTING (Fig.19)
1) After reaching the closing end-of-stroke position, press the "UP" button for 5
seconds.
2) The "SET" led blinks rapidly and the leaf starts to open until it reaches the
opening end-of-stroke.
3) 3 second down time.
4) The "SET" led blinks rapidly and the leaf starts to close until it reaches the
closing end-of-stroke
5) After completing the autoset adjust the opening/closing torque trimmers so
as to obtain the desired sensitivity to the obstacle.
Any input activation (START, RADIO TRANSMITTER, STOP, PHOTOCELL) dur-
ing autosetting will annul the autoset in progress.
10) INTEGRATED RECEIVER
Transmitter versions which can be used:
all Rolling Code transmitters compatible with
10.1)ANTENNA INSTALLATION
Use an antenna tuned to 433MHz.
For Antenna-Receiver connection, use RG8 coaxial cable.
The presence of metallic masses next to the antenna can interfere with radio
reception. In case of insufficient transmitter range, move the antenna to a more
suitable position.
10.2) MANUAL TRANSMITTER PROGRAMMING (Fig.20)
1) Press the "OK" button on the control unit.
2) When the "RADIO" LED blinks, press the transmitter P1 hidden key, and the
"RADIO" LED will stay on permanently.
3) Press the key to be memorised on the transmitter, LED "RADIO" will start
blinking again.
4) To memorise another transmitter, repeat steps 2) and 3).
5) To exit the storage mode, wait until the LED is switched off completely.
10.3) REMOTE TRANSMITTER PROGRAMMING (Fig.20)
1) Press the hidden key (P1) of a transmitter that has been already memorised
in standard mode by means of manual programming.
2) Press the normal key (T1-T2-T3-T4) of a transmitter that has been already
memorised in standard mode by means of manual programming.
3) The courtesy lamp blinks. Press the hidden key (P1) of a transmitter to be
memorised within 10s.
4) The courtesy lamp stays on permanently. Press the normal key (T1-T2-T3-T4)
of a transmitter to be memorised.
The receiver exits the programming mode within 10s., within this time new ad-
ditional transmitters can be memorised.
This mode does not require access to the control panel.
10.4) TRANSMITTER CANCELLATION (Fig.20)
To cancel the control unit memory totally, press the "OK" button on the control
unit for 10 seconds ("RADIO" LED blinking). Correct memory cancellation will be
indicated by the "RADIO" LED staying on permanently. To exit the storage mode,
wait until the LED is switched off completely.
11) EMERGENCY MANOEUVRE
In case of electric power failure or system malfunction, the manoeuvre must be
carried out manually by pulling the wire connected to the carriage, as in fig.21.
For garages which are not provided with a second exit, it is compulsory to fit an
external key release device like Mod. SM1 (fig.22) or Mod. SET/S (fig.23).
12) AUTOMATION CHECK
Before the automation device finally becomes operational, scrupulously
check the following conditions:
• Check that all the safety devices (limit microswitches, photocells, electric edges
etc) operate correctly.
• Check that the door (antisquash) thrust is comprised within the limits set out
by the current standards, and anyway not too strong for the installation and
operating conditions.
• Check that the chain-tightening rubber element is not completely compressed
during the manoeuvre.
• Check the manual opening control operation.
• Check the opening and closing operations using the control devices fitted.
• Check the normal and customised operation electronic logics.
13) AUTOMATION DEVICE USE
Since the automation device can be remotely controlled by means of a radio
control device or a Start button, and therefore when not in sight, all the safety
devices must be frequently checked in order to ensure their perfect efficiency. In
the event of any malfunction, request immediate assistance from qualified person-
nel. Children must be kept at a safe distance from the automation operation area.
14) AUTOMATION CONTROL
The use of this control device allows the gate to be opened and closed automati-
cally. There are different types of controls (manual, radio control, magnetic card
access etc.) depending on the installation requirements and characteristics. For
14 -
BOTTICELLI VENERE
INSTALLATION MANUAL
the various control systems, see the relevant instructions. The automation device
users must be instructed on control and operation.
15) ACCESSORIES
SM1
SET/S External release device with retracting handle for sectional doors measur-
ST
16) MAINTENANCE
Before carrying out any maintenance operation, disconnect the system power
supply.
• Periodically check the tension of the chain/belt (twice a year).
• Occasionally clean the photocell optical elements, if installed.
• Have a qualified technician (installer) check the correct setting of the electronic
clutch.
• When any operational malfunction if found, and not resolved, disconnect
the system power supply and request the assistance of a qualified technician
(installer). When the product is out of service, activate the manual release
device to allow the door to be opened and closed manually.
If the power supply cable is damaged, it must be replaced directly by our
company or our technical service department or by a technician having
similar qualification so as to avoid any risks.
16.1) FUSE REPLACEMENT (Fig.25)
.
WARNING! Disconnect the mains voltage.
Remove the rubber protection from the fuse-carrier. Remove the fuse (Fig.25,
Ref.A) to be replaced and replace it with a new one. After completing this opera-
tion, re-fit the rubber protection.
External release device to be applied to the cremone bolt already fitted
to the overhead door (fig.22).
ing max 50mm (fig.23).
Automatic bolt release device for spring-operated overhead doors. Fitted
to the control arm, it automatically releases the side door bolts (fig.24).

Publicidad

Tabla de contenido
loading

Tabla de contenido