SETTING THE FIRST REMOTE CONTROL
This operation can only be performed when the motor is new, or after a total delete of
the memory.
During this step, power up only one motor at time!
T1: First remote control to be set
+
A
B
T1
REMOTE CONTROL SETTING FUNCTION
Every time you connect the power supply to the motor, you have 3 hours to store the
first remote control. After this time, the ability to store the remote control is disabled.
To reset the timer of the function you have to disconnect and reconnect the power
supply to the motor.
ADJUSTMENT OF THE LIMIT SWITCHES
Tubular motors have an electronic limit switch system with an encoder. This system
ensures great reliability and precision in keeping the positions. Limit switch regulation is
performed simply with the remote control. During setting, the motor moves only as long
as the up or down button is pressed, stopping when the button is released. At the end of
setting, press either the up or down button briefly to move the motor.
It doesn't matter whether or not the rolling shutter has got physical stops in the opening
position and the lockdown hangers in the closing position.
It is possible to choose whether to set the upper limit or the lower limit first.
The correct rotation direction will only be identified after the first position is set so it is
sometimes necessary to use the "up" or "down" button.