Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
Connect the effect to the mains and switch it on via the POWER-switch.
Stand Alone operation
In the Stand Alone mode, the LCC-18 UV/LCC-36 UV can be used without controller. You can do without a
controller as the LCC-18 UV/LCC-36 UV features a built-in microphone, which provides automatic sound
control.
Disconnect the LCC-18 UV/LCC-36 UV from the controller and set the DIP-switch 10 and 11 to ON.
Master/Slave-operation
The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the LCC-18 UV/LCC-36 UV you can find an XLR-jack (DMX Out) and an XLR-plug
(DMX In), which can be used for connecting several devices.
Choose the device which is to control the effects. This device then works as master-device and controls all
other slave-devices, which are to be connected to the master-device via a balanced microphone lead.
Connect the DMX OUT-jack with the DMX IN-plug of the next device.
Set the DIP-switch, as listed in table 1, for the master-device. When the unit is running in Master/Slave
mode, all slave-devices must be set to DMX address 001, and DIP-switches 11 and 12 have to be set to
OFF.