Descargar Imprimir esta página
Ocultar thumbs Ver también para UPSP-5:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

OWNER'S MANUAL
UPSP-5 Portable Transfer Pump
The UPSP-5 portable utility transfer pump is intended for intermittent duty, moving water from one location to
another. The pump can be used to move water from flooded basements, watering lawns and gardens, and drain-
ing water heaters. It can also be used to boost water pressure for washing vehicles, sidewalks, and decks.
Do not use this pump for:
Submersible applications—submersion will immediately damage the pump
Transferring potable water
Effluent or sewage applications
As a pond pump, or for pumping seawater
Water hotter than 77°F (25°C)
Locations classified as hazardous according to the National Electrical
Code (ANSI/NFPA)
The pump motor is equipped with an automatic resetting thermal protector, and may
restart unexpectedly. Thermal Protector tripping is an indication of motor overloading or
overheating. This can be caused by application issues such as an obstructed pump impeller,
pump running dry, excessively high or low voltage supply, or possibly a pump, motor,
bearing, or seal that has reached the end of its useful life.
Please examine your pump carefully to ensure that no damage occurred during shipment. If damage has
occurred, please contact the place of purchase. They will assist you in replacement or repair, if required.
This product is covered by a Limited Warranty for a period of 12 months from the date of original purchase by the
consumer. For complete warranty information, refer to www.littlegiant.com; or, call Technical Support for a
printed copy.
Specifications
Model
Phase
UPSP-5
1
BEFORE GETTING STARTED
This equipment should be installed and serviced by technically
qualified personnel who are familiar with the correct selection
and use of appropriate tools, equipment, and procedures. Failure
to comply with national and local electrical and plumbing codes
and within Little Giant recommendations may result in electrical
shock or fire hazard, unsatisfactory performance, or equipment
failure.
Know the product's application, limitations, and potential haz-
ards. Read and follow instructions carefully to avoid injury and
property damage. Do not disassemble or repair unit unless
described in this manual.
Refer to product data plate(s) for additional precautions, operat-
ing instructions and specifications.
Failure to follow installation or operation procedures and all
applicable codes may result in the following hazards:
Volts
Hz
Amps
115
60
10
Breaker Size
Watts
15 A
1020
Risk of death, personal injury, or
property damage due to explosion, fire,
or electric shock.
Do not use to pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc.
Do not use in explosive atmospheres or hazardous locations
as classified by the NEC, ANSI/NFPA70.
Do not handle a pump or pump motor with wet hands or
when standing on a wet or damp surface, or in water until the
unit is unplugged or electrically disconnected.
If the power disconnect is out of sight, lock it in the open
position and tag it to prevent unexpected application of
power.
Do not submerge motor or mount pump in a location where
motor will come in contact with water. This pump is not
designed for use in showers, hot tubs, spas or other poten-
tially wet locations.
English
EN
HP
Shut Off
1/2
145 ft (44 m)

Publicidad

loading

Resumen de contenidos para Little Giant UPSP-5

  • Página 1 English UPSP-5 Portable Transfer Pump The UPSP-5 portable utility transfer pump is intended for intermittent duty, moving water from one location to another. The pump can be used to move water from flooded basements, watering lawns and gardens, and drain- ing water heaters.
  • Página 2 INSTALLATION Physical Installation High voltages capable of causing severe Risk of bodily injury, electric shock, injury or death by electrical shock are or property damage. present in this unit. • This equipment must not be used by children or persons with •...
  • Página 3 MAINTENANCE Priming and Starting the Pump Priming and Starting the Pump The pump should be located no more than 15' away from the water source. Remove the prime plug (marked "PRIME") and fill the pump body with water. Tighten the plug. 2.
  • Página 4 MAINTENANCE MAINTENANCE Storage Storage Storage If pump is being stored for more than 30 days: Allow the pump to cool completely. 2. Remove priming plug from the pump housing and remove the suction discharge hoses and/or piping. Invert the pump upside-down and drain any water left in the pump. 3.
  • Página 5 MANUEL D’UTILISATION FRANÇAIS Pompe de transfert portative UPSP-5 La pompe de transfert utilitaire portative RLMPTC est conçue pour un service intermittent et permet de déplacer de l’eau d’un endroit à un autre. La pompe peut être utilisée pour retirer l’eau des sous-sols inondés, arroser les pelouses et les jardins et drainer les chauffe- eau.
  • Página 6 INSTALLATION Installation physique Risque de blessure grave ou de mort par Risque de blessure, de choc électrocution. électrique ou de dégâts matériels. • Pour réduire le risque de choc électrique, débranchez l’alimenta- • Cet équipement ne doit pas être utilisé par des enfants ou des tion avant de travailler sur le système ou autour de celui-ci.
  • Página 7 ENTRETIEN Amorçage et démarrage de la pompe Amorçage et démarrage de la pompe La pompe doit être située à au plus 15 pi de la source d’eau. Retirer le bouchon d’amorçage (marqué « PRIME « ) et remplir la pompe avec de l’eau. Resserrer le bouchon. 2.
  • Página 8 ENTRETIEN ENTRETIEN Entreposage Entreposage Entreposage Si la pompe est entreposée pendant plus de 30 jours : Laisser la pompe refroidir complètement. 2. Retirer le bouchon d’amorçage du boîtier de la pompe ainsi que les tuyaux d’aspiration et de refoulement. Mettre la pompe à l’envers et drainer toute l’eau restante dans la pompe.
  • Página 9 MANUAL DEL PROPIETARIO ESPAÑOL Bomba portátil de transferencia UPSP-5 La bomba portátil de transferencia para servicios públicos RLMPTC está diseñada para tareas intermitentes, y la remoción de agua de un lugar a otro. La bomba se puede utilizar para retirar agua de sótanos inundados, regar césped y jardines, y drenar calentadores de agua.
  • Página 10 INSTALACIÓN Instalación física Esta unidad tiene voltajes elevados que Riesgo de lesiones corporales, son capaces de provocar lesiones graves descargas eléctricas o daños al o muerte por descarga eléctrica. equipo. • Para reducir el riesgo de descarga eléctrica, desconecte la •...
  • Página 11 MANTENIMIENTO Cebado y arranque de la bomba Cebado y arranque de la bomba La bomba debe ubicarse a no más de 15 pies (4 m) de la fuente de agua. Retire el tapón de cebado (marcado como “PRIME”) y llene el cuerpo de la bomba con agua. Apriete el tapón. 2.
  • Página 12 MANTENIMIENTO MANTENIMIENTO Almacenamiento Almacenamiento Almacenamiento Si la bomba se almacena por más de 30 días: Permita que la bomba se enfríe por completo. 2. Retire el tapón de cebado de la carcasa de la bomba y las mangueras o tuberías de descarga de succión. Ponga la bomba al revés y drene el agua que quede en su interior.