13 Technical data
This section contains an excerpt of the most important technical data. Further
technical data can be found on the product page in the Emerson store.
General
Weight
G1/4"M
G1/4"F
Housing material
Material display
Seal display
Ambient temperature for storage
min. ... max.
Ambient temperature during operation
min. ... max.
Type of pressure
Type of measuring cell
Overall accuracy (23 °C)
Max. temperature error (-25 ... +80 °C)
Long-term drift
Vibration resistance according to
EN 60068-2-6
Shock resistance according to
EN 60068-2-27
Assembly
Mounting orientation
Wrench size of pressure connection
Electrics
Protection class
Degree of protection
Electrical connection
Operating voltage
Local power consumption
Short circuit resistance
Reverse polarity protection
Outputs
Output 1 (pin 4)
Output 2 (pin 2)
Max. output current
Response time
Standards and directives complied with
Standard / directive Description
EMC directive
Electromagnetic compatibility of electric products and electronic
2014/30/EU
products
RoHS Directive
Restriction of the use of certain hazardous substances in electrical
2011/65/EU and
and electronic equipment
2015/863/EU
EN 50178
Electronic equipment for use in power installations
EN 60068-2-6
Environmental influences, part 2-6: Test methods – Testing Fc: Oscil-
lation (sinusoidal)
EN 60068-2-27
Environmental influences, part 2-27: Test methods – Testing Ea and
guide: Shock
EN 61000-6-2
Electromagnetic compatibility (EMC); part 6-2: Generic standards –
interference immunity for industrial environments
EN 61000-6-4
Electromagnetic compatibility (EMC); part 6-4: Generic standards –
interference emission for industrial environments
AVENTICS™ PE7 | R412028734-BAL-001-AB | English
Specifications
191 g
244 g
Stainless steel 1.4301 / 1.4305
Glass, shatterproof installed
PE
+30 ... +85 °C
-25 ... +80 °C
The display switches off at 80 °C display tempera-
ture.
Relative pressure
Ceramics
±0.5 % FSO
±1.5 % (< 25 bar)
≤ 0.1 % / a
20 G, 10 ... 2000 Hz, XYZ
50 G, 11 ms, XYZ
Specifications
Any
27
Specifications
III
• IP65
• IP67
• IP68
Plug connector M12x1, 4-pin
9 ... 30 V DC
9 V: only digital output
13 V: analog output
18 V: according to IO-Link standard 61131-9
UL: only with "Class 2" power supply
< 30 mA
Yes
Yes
PNP / NPN / PP or IO-Link
PNP / NPN / PP or analog (0 ... 10 V / 1 ... 10 V /
4 ... 20 mA)
200 mA per output
< 3 ms
Standard / directive Description
UL approval
E473614
Communication interface
Display
IO-Link
IO-Link status display
Switching state display
SIO mode
Process data
Baud rate
Minimum cycle time
ISDU
Pneumatics
Measurement
range
Medium
Material of fluid connection
Material of measuring cell
Material of seals
Overload pressure
-1 ... +1 bar
0 ... 25 bar
Burst pressure
-1 ... +1 bar
0 ... 25 bar
Medium temperature
Specifications
• 0.96" TFT touch display
• 160 x 80 px
1.1
Color display
1x color display per output
Yes
4 bytes: 16-bit pressure value, 4-bit device status, 2-
bit switching state Out 1 / Out 2
COM2 (38.4 kBaud)
3.5 ms
Yes
Specifications
Fluid group 2
Stainless steel 1.4404
Ceramics Al
O
96 %
2
3
See material number
10 bar
100 bar
20 bar
140 bar
-25 ... +100 °C
17