Output voltage
Charging current
Protection class
A) The working range increases depending on how well the laser light is
reflected from the surface of the target (scattered, not reflective) and with
increased brightness of the laser point to the ambient light intensity
(interior spaces, twilight). In unfavorable conditions (e.g. when measuring
outdoors at intense sunlight), it may be necessary to use the target plate.
B) For measurements from the rear measuring-tool edge. In unfavorable
conditions (e.g. at intense sunlight or an insufficiently reflecting surface),
the maximum deviation is ±10 mm per 80 m (±7/16 in per 265 ft). In
favorable conditions, a deviation influence of ±0.05 mm/m (±1/64 in per
26 ft) must be taken into account.
C) For measurements with the rear side of the unit as reference, the max.
measuring range is ±60°.
D) After calibration at 0° and 90° with an additional maximum pitch error
of +/- 0,01°/° until 45°.
E) In the continuous measurement function, the maximum operating
temperature is 104°F (+40°C).
F) at 77°F (25°C)
G) For a new and charged battery without display illumination and tone
signal.
Please observe the article number on the type plate of your battery
charger. The trade names of the individual battery chargers may vary.
Please observe the article number on the type plate of your measuring
tool. The trade names of the individual measuring tools may vary.
The measuring tool can be clearly identified with the serial number 18
on the type plate.
2 609 120 422
-17-
2.3" x 24" x 1.2"
5.0 V=
500 mA
2 609 120 422
5.0 V=
500 mA