b)
in front of the furnace door, in the radiation area, there must be no flammable or heat-sensitive objects or material at a distance
of less than 100 cm. This distance can be reduced to 40 cm where a rear-ventilated, heat-resistant protection device is
installed in front of the whole component to protect;
c)
If the product is installed on a no totally refractory floor, one must foresee a fireproof background. The floors made of
inflammable material, such as moquette, parquet or cork etc., must be covered by a layer of no-inflammable material (size
according to regional law, see
The ash drawer must always be inserted when the appliance is in operation.
The solid combustion residues (ashes) must be collected in a metal container that is hermetically sealed and fire resistant. The
appliance must never be lit in the presence of gaseous emissions or vapours (for example: glue for linoleum, petrol, etc,). Do not
place flammable materials in the vicinity of the appliance.
During the combustion, thermal air is emitted by involving the heating of areas, door and glass hearth, of the door handles or controls,
of the smokes pipe and, in case, of the front part of appliance. Avoid to touch those parts without a protective clothing or without
accessory tools (gloves resistant to heat, control devices).
Ensure children are aware of these dangers and keep them away from the furnace when it is on.
Warn children that the device becomes very hot and that it must not be touched.
When using the wrong fuel or one which is too damp, due to deposits present in the flue, a flue fire is possible.
FIRST-AID MEASURES
Should any fire arise in the stack or in the flue:
a) Close the feeding door.
b) Close the registers of combustion air
c)
Extinguish the fire using carbon dioxide fire-fighting means (CO
d) Seek immediate intervention of FIRE BRIGADE.
DO NOT ExTINGUISH FIRE USING WATER JETS. When the flue does not burn any more please arrange an examination by a
specialist in order to find possible cracks and permeable points.
BEAM PROTECTIONS
Considering the irradiation of the hearth, it is necessary to be particularly careful in protecting the beams while designing your stack.
Consider the proximity of beams to the external surfaces of the hearth, on one side, and the irradiation of the glass door, usually very
close to the beams, on the other side. In any case, it has to be considered that the internal or lower surfaces of this beam in flammable
material must not come in contact with temperatures higher than 65 °C.
WARNING: We cannot be made liable for a wrong operation of the plant, when it does not comply with the provisions of
these instructions or when it uses additional products not suitable for this device.
TECHNICAL DESCRIPTION
The appliance is made up of a steel chamber completely soldered and hermetic. The hearth is coated by single cast-iron sheets
and refractory plates (NORDIKER).
made up of a galvanized steel carter external to the heating body. Inside the hearth there are a grate holder and the
related grating, both made of very thick cast-iron and easily extractable.
appliance.
The insert is equipped with a sight door with ceramic glass (resistant up to 700°C). This allows a charming sight on burning flames.
Moreover, in this way, any possible leak of sparks and smoke is avoided. Under the hearth grating there is a easily extractable ash
drawer, also when the appliance works.
ACCESSORIES
The heating of the room occurs:
a) by convection: the passage of air through the coating and the covering hood releases heat in the room.
b) by radiation: through the sight glass and the steel body, heat is radiated into the room.
by forced convection: a ventilation kit suitable to improve the distribution of heat by ventilation only either of the installation
c)
room or of the adjacent local.
The device is equipped with registers of primary and secondary air, with which it is possible to adjust the combustion air.
1A - PRIMARY air register
With the air register located under the door of the hearth (on the left), it is possible to adjust the air flow through the ash drawer and
the grating in direction of the fuel. The primary air is necessary for the combustion process during the ignition. In order to open the
passage of primary air the lever should be completely pulled.
The ash drawer has to be emptied regularly, so that ash cannot hinder the intake of primary air for the combustion. Primary air is
also necessary to keep fire live.
During the combustion of wood, the primary air register must be opened only a few, since otherwise the wood burns quickly and
the device can overheat (see chapter NORMAL OPERATION).
22
Picture
1).
The appliances are equipped with an integrated air circuit for the recovery of the heat
POKER
SERIES
(Picture
8)
dust).
2
Picture 2
gives some examples of execution.
The appliance works as an intermittent operating
VENTILATION
GLOVE
SERIES
SERIES
ENgLIsH