Programming And Startup; Controls And Commands - Erreka AM600S Manual Del Instalador

Cuadro de maniobra para accionador monofásico
Ocultar thumbs Ver también para AM600S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

PROGRAMMING AND STARTUP

1

CONTROLS AND COMMANDS

SW2 Functions during programming (DIP1=ON)
SW2 Functions during use (DIP1=OFF)
DIP2: advance warning
DIP2=ON: the flashing light comes on and the
operation begins after a 3 second warning.
DIP2=OFF: the flashing light comes on and the
operation begins immediately.
DIP3: step-by-step or collective opening
DIP3=ON: step-by-step opening (the panel obeys
the key commands during opening).
DIP3=OFF: collective opening (the panel does
not obey the key commands during opening).
DIP4: automatic or step-by-step closing mode (in
total and pedestrian operation)
DIP4=ON: automatic mode (the gate closes
automatically after the standby time has passed,
which is adjusted using T.E.).
DIP4=OFF: step-by-step mode (the gate only
closes when receiving the key command).
DIP5: automatic mode optional (only if DIP4=ON)
DIP5=ON: during standby, the gate obeys the
key commands (this can be closed before standby
time finishes).
DIP5=OFF: the gate cannot be closed until
standby time finishes.
SW1
Main switch
SW2
Programming DIPs
ST1
Total operation mini-pushbutton
ST2
Pedestrian operation mini-pushbutton
PUL1
Close mini-pushbutton
PUL2
Open mini-pushbutton
T.LG
Garage light time regulation (3-90 seconds)
T.E
Standby time regulation (0-90 seconds)
(only functional in automatic mode)
P.M
Torque adjustment
DIP2=ON: total open/close programming (see page 27)
DIP3=ON: pedestrian open/close programming (see
page 28)
DIP4=ON: total opening radio code programming (see
page 26)
DIP6=ON: pedestrian opening radio code
programming (see page 26)
DIP6: opening photocell testing (SG.A)
DIP6=ON: testing enabled
DIP6=OFF: testing disabled
DIP7: encoder activation
DIP7=ON: encoder enabled
DIP7=OFF: encoder disabled
DIP8: slowdown function
DIP8=ON: the gate reduces its speed before
reaching the stopper.
DIP8=OFF: the gate reaches the stopper at high
speed.
DIP9: closing photocell testing (SG.C)
DIP9=ON: testing enabled
DIP9=OFF: testing disabled
DIP10: type of slowdown (only if DIP8=ON)
DIP10=ON:
progressive
(deceleration ramp 1.5 seconds)
DIP10=OFF: sudden deceleration
English
deceleration
Control board AM600S-AM606S
25

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Am606s

Tabla de contenido