Descargar Imprimir esta página

Eneo VKC-1310S Instrucciones De Manejo página 16

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Connection and Operation
Rear view 12VDC/24VAC
D
P
B
E
C
F G
B
PL
C
Power supply /
power cord
D
LEVEL
P
PHASE
E
LENS
F
1 ... 8
G
VIDEO OUT
HO,
Camera mount
HU
N
Dust cover
K,L
C/CS mount
M
Locking screw
230VAC
D P B
E
C
F G
LED-indicator B lights green when the camera is switched on.
12VDC/24VAC power supply. Power supply unit see „Specifications".
230VAC power supply via power cord C. Make the connections first, then switch
the unit on.
Output level adjustment with potentiometer D for DC controlled lenses.
Potentiometer P for phase adjustment for mains sychronization.
Connection E for DC or AI controlled lenses. Connect the cable of lenses
with automatic iris control to the supplied 4 pin DIN plug. (Only for AI lenses
which are designed for operation with 9-12VDC and 50mA max.)
DIP-Switch F to change the settings described under „DIP-Switch settings".
Video output G (BNC) for connection of external units (e.g. monitor, 75Ohm).
1/4"-20UNC-thread HO/HU for camera mounting, for example on a tripod,
ceiling mount or P&T head.
To protect the CCD-sensors the camera module. Always attach dust cover N
when no lens is mounted.
CS mount L for CS mount lenses. Insert the supplied C mount ring K
if C mount lenses are used.
To adjust the flange focus open screw M, turn the at CS mount ring L until the
focus maximum is achieved and fasten the screw again.