PowerPainter 90 EXTRA
Correction of Malfunctions
Problem
Cause
•
The sprayer does
The sprayer is not plugged in.
•
not start.
The device is switched off.
•
The sprayer was turned off while still under
pressure.
•
No voltage is coming from the wall plug.
•
The extension cord is damaged or has too low
a capacity.
•
Device overheated
•
There is a problem with the motor.
•
The spray device
The unit will not prime properly or has lost
runs but does not
prime.
•
suck up any paint
The paint bucket is empty or the suction tube
when the selector
is not totally immersed in the paint.
•
switch is set to the
The suction tube is clogged.
•
PRIME position.
The suction tube is loose at the inlet valve.
•
The inlet valve is stuck.
•
The inlet valve is worn or damaged.
•
The PRIME/SPRAY valve is plugged
•
The sprayer draws
The spray nozzle is worn.
•
up paint but the
The inlet filter is clogged.
•
pressure drops
The gun filter is plugged.
when the gun is
•
triggered.
The paint is too viscous or contaminated.
•
The inlet valve is worn or damaged.
•
The spray gun leaks
Internal parts of the gun are worn or dirty.
•
The nozzle
The nozzle was assembled incorrectly.
•
assembly leaks
A seal is dirty.
•
The spray gun will
The spray nozzle or the gun filter is plugged.
•
not spray.
The spray tip is in the reverse position.
•
The paint pattern is
The paint is too viscous or contaminated.
•
tailing.
The spray nozzle or the gun filter is plugged.
•
The spray nozzle is worn.
•
The inlet filter is clogged.
•
The gun filter is plugged.
•
The inlet valve is worn or damaged.
Remedy
➞ Plug the sprayer in.
➞ Turn the ON/OFF switch to ON.
➞ Perform pressure relief procedure and set selector
switch back to SPRAY
➞ Properly test the power supply voltage.
➞ Replace the extension cord.
➞ Switch the device off, turn the selector switch to the
PRIME position (vertical), remove the mains plug and
allow device to cool down for min. 30 minutes. Eliminate
the cause of overheating, e.g. covered ventilation
slot.
➞ Please contact Wagner Service
➞ Try to prime the unit again.
➞ Refill the bucket or immerse the suction tube in
paint.
➞ Clean the suction tube.
➞ Tighten it securely.
➞ Press the inlet valve pusher. If the problem is not
solved, clean the inlet valve.
➞ Replace
➞ Please contact Wagner Service
➞ Replace the spray nozzle with a new nozzle.
➞ Clean the inlet filter.
➞ Clean or replace the filter. Always keep extra filters on
hand.
➞ Thin or strain the paint.
➞ Replace
➞ Please contact Wagner Service
➞ Check the tip assembly and assemble properly
➞ Clean the seal.
➞ Clean the spray nozzle or gun filter.
➞ Put the nozzle in the forward position.
➞ Thin or strain the paint.
➞ Clean the spray nozzle or gun filter.
➞ Replace the spray nozzle with a new nozzle.
➞ Clean the inlet filter.
➞ Clean or replace the filter. Always keep extra filters on
hand.
➞ Replace
GB
29