IV. Installation
Step 1: Attaching the hoses
We recommend that you first arrange all parts you need in front of you.
You will need a 3/8" or 1/2" supply which is also connected to your
kitchen tap.
Recommended for installation of the wall mount: two screws (e.g. 5 mm in size)
and two wall plugs (if necessary). Please use appropriate screws and wall plugs
for the type of wall.
Please follow the diagram below and the steps in the right order.
A. Connect the water supply line (see bag "WATER IN")
a)  Turn off the cold water supply.
b)  Put "water in" hose (3) in place.
c)  Now connect one end of the hose (2a) to the filter head (6) inlet using the
thread insert 3/8" including flow restrictor to plug-in (4) and add the fixing
clip (5). This is labelled "WATER IN" and marked with an arrow. Make sure the
thread insert is pressed to the limit and the fixing ring is seated correctly!
d)  Now connect the other end of the hose (2b) to the back flow preventer (11)
and the cold water supply. If you cannot connect the end of the back flow
preventer (11) use the adapter (12) supplied with related gasket (15).
B. Connect the tap supply line (see bag "WATER OUT")
a)  Put hose (8) in place.
b)  Now connect the correct end of the hose (2c) to the filter head (6) inlet using
the thread insert 3/8" to plug-in (7) and add the fixing clip (5). This is labelled
"WATER OUT" and marked with an arrow. Make sure the thread insert is
pressed to the limit and the fixing ring is seated correctly!
c)  Now connect the other end of the hose (1) to the hose which is already
attached to the kitchen tap for cold water. If you cannot connect the end of
the hose (2c) use the adapter (13) supplied with related gaskets (14 and 15).
6
Cold water supply
15
12
5
11
4
2a
3
2b
15
13
8
14
1
* UK: see
page 10
Bag "WATER IN"
6
Bag
"filter head"
Bag "WATER OUT"
5
2c
7

Publicidad