Descargar Imprimir esta página

GYS GYSFLASH 30-12 HF Manual Del Usuario página 15

Ocultar thumbs Ver también para GYSFLASH 30-12 HF:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
ADVANCED MENU
This menu controls the advanced parameters of the charger. To move from one parameter to another push the Select key :
Activation «Change battery» > Activation «Power Supply» > Activation «Expert Curve» (> Adjusment of the
SELECT
«Expert Curve» parameters)
• CHANGE BATTERY mode activation:
To activate the CHANGE BATTERY mode, select «ADVANCED MENU |
Change bat: ON». Now this mode will be accessible from the mode list.
• POWER SUPPLY mode activation:
To activate the POWER SUPPLY mode, select «ADVANCED MENU | Power
Supply: ON». Now this mode will be accessible from the mode list.
• «EXPERT» curve activation:
To activate the «RECOV» curve, select «ADVANCED MENU | Expert curve:
ON». Now this curve will be available in the charging curves list from the
CHARGE mode.
• Parameters adjustment of the «Expert» curve:
If the charging curve is activated, the charging curve parameters can be
adjusted (type IU
I
U):
0
0
- Ucharge: Charge voltage adjustable from 12.0 to 16.0V (Step 7).
- Urecovery: Recovery voltage adjustable up to 30.0V.
If the value «OFF» is selected the recovery function is inactive (Step 2
and 4).
- Ufloating: Floating voltage adjustment.
If the value «OFF» is selected the floating function is inactive (Step 9).
- Trecovery: Maximum time for shorted cells recovery, adjustable from
1h to 12h (Step 2).
- Trefresh: Time for the refreshing phase adjustable from 1h to 12h. If
the value «OFF» is selected, the refresh function is not activated (Step 8).
- T desulfat: Maximum time adjustable from 1h to 12h of the desulfation
phase (Step 4).
- T ch_max: Maximum charging time (Step 7 and 8).
- T ch_min: Minimum charging time (Step 7 and 8).
- Urefresh: Maximum voltage during the cooling phase (Step 8).
- OCP (Over Charge Protection): Maximum percentage of the nominal
capacity which can be injected before the protection begins.
aWarning:
When charging in-situ, a «Urecovery» or «Urefresh» too high
might damage the electronics of the vehicle. We advise NOT to
adjust these settings above 15V.
To save and validate the new settings, select «ADVANCED MENU» | save? Yes»
Push the «MODE» key to exit the «Configuration» menu.
GYSFLASH 30-12 HF
ADVANCED MENU
ADVANCED MENU
Change bat.:
OFF
ADVANCED MENU
Power Supply: OFF
ADVANCED MENU
expert curve:
OFF
OFF
ON
EXPERT CURVE
Ucharge:
14.3V
EXPERT CURVE
Urecovery:
OFF
EXPERT CURVE
U oating:
OFF
EXPERT CURVE
T recovery*:
5h
EXPERT CURVE
T desulfat:
12h
EXPERT CURVE
Tch_max:
16h
EXPERT CURVE
Tch_min:
0h
EXPERT CURVE
T refresh:
5h
EXPERT CURVE
U refresh:
17.0V
EXPERT CURVE
OCP:
200%
ADVANCED MENU
Save?
No
RETURN
EN
ON
OFF
ON
OFF
ON
OFF
12.0V
12.1V
...
16.0V
OFF
Uch
...
29.9V
30.0V
OFF
12.0V
12.1V
...
Uch
1h
2h
...
12h
1h
2h
...
12h
1h
2h
...
36h
0h
1h
...
Tch_max
OFF
1h
2h
...
12h
Uch
...
30.9V
31.0V
100%
...
245%
250%
Yes
No
15

Publicidad

loading