Connecting the inverter
6
Connecting the inverter
6.1
Connecting the MI150
The inverter is connected via a plug connected to a 12 V socket (MI150-012)
or a 24 V supply (MI150-024). The middle pin of the plug (fig. 1 4, page 3)
must be connected to the positive wire and the two side brackets of the plug
(fig. 1 5, page 3) must be connected to the negative wire.
Caution
Make sure the plug is firmly connected in the socket. If the connec-
tion is loose, the plug may heat up.
Caution
The rating of the socket, the supply cable and the fuse must be at
least 15 amps. Do not put in a fuse with a higher rating.
6.2
Connecting the MI300 and MI500
Caution
To set up the inverter, connect the red cable (fig. 1 4, page 3) to
the positive pole (+) of the battery and the black cable (fig. 1 5,
page 3) to the negative pole (–) of the battery. Make sure the bat-
tery poles are clean when connecting the terminals.
Caution
Only extend the connection line with cables with a cross section
that is equal to or greater than that of the connection line.
Caution
Do not reverse the polarity. Reversing the polarity of the connec-
tions will cause a great spark and the internal fuses will melt.
22